MLLENN|UM trtEVELOPERs FORM-2A [See Maha RERA order no' of 2018] ENG|NEER'SCERT|F|GATEFoRQUAL|TYASSURANCE (Site suPetvisor's certificate) Date- 0910412019' To, Millennium DeveloPers Shop No. 21, 1't Floor, "Metro 9" Building, OPP, Park Street, Aundh Ravet Road, - Rahatni, Pune 411017 ' (Certificate no 1 for the quarter ending --- 2019) Subject: Certificate for quality of materia ! workmanship for the Work of No' of Buildin on the plot bearing Sr. No. 129' situated at marcated by its boundaries to the North Gat DeveloPers. Reference:MahaRERARegistrationNumber.P52l00000055. Sir, of this I Mr. Mangesh Hargude have undertaken an assignment of supervision real estate Project. 1. Our ResPonsibilitY: - permission and as per the To carry out the work in accordance with the development of work and to carry out material approved ptan anJ submit certificaG'oi:rrp"*ision testing in-situ ol. in g," authorized laLoratory and to ensure quality of work and 1. Material Testinq:- l/we have applied following mandatory ;hecks on the basic materials' used in the construction' ,'METRO 9'', opp. Park Street, Aundh-Ravet Road, Shop No. 2!,|'stFloor, Rahatni, Pune 4L10L7 Tel': +91' 20 64100003' Email : admin@millenniumdv. com MLLENNUM DEVELOPER5 i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lS/85/NBC code, oras per industry standards and its results are within the permissible limits. ii. Goarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant IS/BS/NBC code or asper industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per lS 5454:1978 or as per other relevant |S/8S/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/Ready-m ix Concrete- It has been tested forcompressive strength forvarious periods as per 15456:2000 and lS 1199 or as per other relevant lS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- lt has been tested as per lS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3, Electrical Materials and workmanship: - Works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. Shop No. 27,l'st Floor, "METRO 9", Opp. Park Street, Aundh-Ravet Rodd, Rahatni, Pune 411017. Tel.: +91,20 64100003. Email : admin@millenniumdv.com N/il-Lef{NIUM trlEVELOPERs 4. Structural engineer: - Promoters has engaged structural engineer Mr.Satyakam Ghokhle of Equicom Structural Consultants having Licenses ro.:, having office at 11lC - 2, Paya Society near City lnternational School, Aundh, Pune-411007. Contact: 8446159643. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per is 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of works which were not conforming to the standard specifications and which were not rejected. You Signature of r (Site Supervisor) Name: Mr. Mangesh Hargude Phone no.9225937054 Place: Pune Shop No. 2'1.,1'st Floor, "METRO 9", Opp. Park Street, Aundh-Ravet Road, Rahatni, Pune 411017. Tel.: +91,20 64100003. Email : admin@millenniumdv.com