FORM-2A ENGINEER’S CERTIFICATE FOR QUATITY ASSURANCE To, Karda Constructions Limited 2nd floor, Gulmohar status, above Business Bank, Samarth Nagar, Nashik-422005 Quality Assurance Certificate (Certificate no- for the year ending 30.09.2021) Subject: Certificate for quality of materials used and quality of Construction and workmanship for the Work of 1 Buildings of the project Hari Sanskruti Phase I [MAHARERA Registration Number: P51600001194] situated on the S NO 248/1 to 6/1+2+3+4 (Part) demarcated by its boundaries Adj. S. No. 249 to the North, Approved Layout No. 3/12 to the South, Approved Layout No. C-3/21 & 12M Wide Colony Road to the East, Adj. S. No. 247 & Proposed 60M D. P. Road to the West of Division Nashik, Village Deolali, Taluka Nashik, District Nashik PIN 422 101 admeasuring 6873.28 sq.mts area being developed by KARDA CONSTRUCTIONS LIMITED. Reference: MahaRERA Registration Number: P51600001194 Sir, I, Mr. Chetan Sonawane have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. 1. Material Testing- I, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lS/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate – It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 2430:1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks – They have been tested for water absorption, crushing strength etc. as per lS 5454:1978 or as per other relevant lS/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete / Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per lS 2062:2011 or as per other relevant ls/Bs/NBC code or as per industry standards for tensile strength, elongation and gauSe length etc. and its results are within permissible limits. vi. Testing of Other materials – Other materials like sand, crushed sand, floor tiles, fixtures and {ittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the lndustry for a particular material. 2. Workmanship:- I hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - Works of all the electrical wiring/ connections / lift installation / other electrical installations have been carried out under authorized /registered electrical en8ineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Buildin8 codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer Mr. Sanjeev Patel having Licenses no 924889 dated 06.01.2021 having office at Navrang Complex, near Dwarka Hotel, Nashik-422011, cell no 9823191590 The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per IS 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected Yours Faithfully, Signature of Engineer (Site Supervisor) Name: Mr. Chetan Sonawane License no.(if any)- NA Phone no : 9545570000 Place: Nashik