Mr. R"ajendra Patil B.E.Civil a T Flat No. B-25, Suyojit Lawns phase-ll, Rathi Amari, Ncar Mahatlrla Nagar, Nashik-4220O7. Mob. No. 9819667298 Ernail - rajendra.pati@suyojit.com FORM-2A ISee Maha RERA order no. of 2018] ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site su pervisor,s certifi cate) To, The Directors Sun Infrastructure Pvt. Ltd., F-1l2, Suyojit Heights, Opp. Rajiv Gandhi Bhavan, Sharanpur Road, Nashik Quali ty Assuranc e Certificate (Certificate no ps160001sos2 for the quarter ending June-2021) Subject: Certi ficate for quality of materials used and quality of Construction and workm anship for the Work of of "S uyojit Viridian ValIis Phase-I E-6, VIVIDE" No. of Building(sl 1 of the project situated on the Plot bearing Out of Su rvey No. S. o.l45/1, S.No.145 /3, S.No.a49/1, S.No.l49 /2, S.No.151, S.No.1SZ, S.No.1S 5/2, (latitude and longitude of the end pointsJ 12 MTRS ROAD to the North, proposed Building E 7 to the South, Margi nal Space and Reaming Area of S No 145 to the East, BUILDING E5 to the West of Di vision Nashik Situated at Village Makamalabad, Taluka & District Nashik, within the iurisdiction of Sub Registrar Nashik, and within limits of Nashik Municipal Corporation, Nashik, PIN 4220O7 admeasuring 2867.O4 sq.mts. area being developed by Infrastructures Pvt. Ltd] [Sun Reference: MahaRERA Registration Number- ps1600019os2 Sir, I Mr. Rajendra Patil have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out materiai testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testin q:- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per ls code 3535:1986 or as per other retevant ts/BsiN-BC code, or standards and its results are within the permissible limits. ""-r"rlil;try ii. Coarse aggregate - It has been tested, for dereterious materiars, cray rumps, crushing varue, impact varue as per ls 24301 1986 or as per other rerevant lsiBS/NBi code or rJ p",. inausiry sianoaras and its results are within the permissible limits. ii i. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per ls 5454:i97g or as per other relevant |S/8S/NBC code or as per induslry staidards and its results are within permissible limits. iv. Concrete/Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and ls 1 199 or as per other relevant IS/BS/NBC codes, as per industry standards and its resutts are within permissible limits_ v. Steel for concrete- It has been tested as per ls 2062:20'1 1 or as per other relevant lsiBS/NBC code or as per industry standards for tensile strength, elongalion and gauge length etc. ano its resutts are within permissible limits. vi. Testing of Other materials other materials like sand, crushed sand, floor tiles, fixtures and {fiftings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant tS/BSiNeC code or as per standards laid down by the industry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - Works of all the electrical wiring/connections/lift installation/other electrical installatjons have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.Sl B.S/ National Building codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer M/s. Shanghvi & Associates Consultants pvt Ltd having Licenses no having office no 02226144g32. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultaiion with soil consultant. The formwork and concrete mix design has been done as per ls .10262:200g or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5, Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. Yours Faithfully, No lNo?.b- Dooe- 6u Signature of Engineer (Site Supervisor) Mr. Rajendra Patil t--tro r-o - *y-*\-Zl lp {q6e--zr Phone no.9819667298 Place: Nashik