Mr. Rajendra Patil B.E.Civil I Flat No. B-25, Suyojit Lawns Phase-II, - I l- >a I Rathi Amari, Near Mahatma Nagar, Nashik-422OO7. Mob. No. 9419667294 Email * rajendra.patil@suyojit.com FORM-2A I See Maha RERA order no. of 2018] ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certifi cate) To, The Directors Sun Infrastructure Pvt. Ltd., F-1l2, Suyojit Heights, Opp. Rajiv Gandhi Bhavan, Sharanpur Road, Nashik Quality Assurance Certificate (Certificate no psl600019052 for the quarter ending December-2021) Subject: Certificate for quality of materials used and quality of Construction and workmanship for the Work of of "Suyoiit Viridian Vallis Phase-II E-6, VIVIDE" No. of Building[s] 1 of the Project situated on the Plot bearing Out of Survey No. S.No.145/1, S.No.145/3, S.No.149/1, 5.No.149/2, S.No.151, S.No.152, S.No.155/2, [latitude and longitude of the end points) 12 MTRS ROAD to the North, Proposed Building E7 to the South, Marginal Space and ReamingArea of S No 145 to the East, BUILDING ES to the West of Division Nashik Situated at Village Makamalabad, Taluka & District Nashik, within the jurisdiction of Sub Registrar Nashik, and within limits of Nashik Municipal Corporation, Nashik, PIN 422007 admeasuring 2867.04 sq.mts. area being developed by [Sun Infrastructures Pvt. Ltdl Reference: MahaRERA Registration Number- P516000190s2 Sir, I Mr. Rajendra Patil have undertaken an assignment of supervision of this real estate project 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testinq:- I on the basic materials' used in the l/we, have applied following mandatory checks construction. i. Cement- It has been tested for its fineness, soundness' settilg]i"' compressive strength etc as per ts code 3535:1986 o'. p"i-#"i-r"t"rrnt rslastNec code, or as per industry standards ". and its results are within the permissible limits' ii. Coarse aggregate - lumps' crushing value'.impact.value as It has been tested, for deleterious materials' clay code or ai per industry standards oer ls 24301 1986 or as p";;il;;;ete';ni islasNec and its results are within the permissible limits' iii. Bricks, blocks - Theyhavebeentestedforwaterabsorption,crushing.strengthetc'asperls5454:'l978or as per other relevant .SIAS/NBC coA; or r" p", induitry sta-ndards and its results are within permissible limits. iv. Concrete/Ready-mix Goncrete' lthasbeentestedforcompressiveStrengthforvariousperiodsaSperl5456:2000andlS per industry standards and its results 1 1 99 or as per other ,.ErJni iSISS/NBC codes, as are within Permissible limits v. Steel for concrete- lthasbeentestedaSperls2062:20llorasperotherrelevant|S/BS/NBCcodeorasper and gauge length etc. and its results are industry standards to, tensiL-=tiJ"gih, .l."g"ii"n within permissible limits. vi. Testing of Other materials othermaterialslikesand'crushedsand,floortiles,fixturesandffittings'pipesandSanitary p-i""t.onform to relevant |S/BS/NBC code or as fittings etc. (List out it"m=ii in ini. "rr bv tfie "Ii industry for a particular material' ;;'il;;;;=tlaid down 2. WorkmanshiP:- l/weherebycertifythatworkhasbeencarriedoutunderoursupervision.Wefurthercertify up to the mark and the work has been that workmanship and q,"fiy'it ""ti?""tgw and as per relevant code of practice. acceptable within the p"r.i"Jiurl limits of deviations 3. Electrical Materials and workmanship: - electrical installations have works of all the electrical wiring/connections/lift installation/other and its records has been been carried out under electrical engineer "rinlr""LJliullsiered maintained. The materiats u""J"ontoi, to the relevant l.57 B'Si National Building codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer M/s. Shanghvi & Associates Consultants Pvt Ltd having Licenses no having office no 02226144832. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per ls 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. Yours Faithfully, No uJozrk Done JrL" s i g natu re or e n g i nee, [s it.s u pervisor) in thrs perioJ Mr. Rajendra Patil Phone no.9819667298 Place: Nashik