FORM-2A lsee MahaRERA order No. of 20181 ENGINEER,S CERTIFICATE FOR QUATITY ASSURANCE (Site Supervisotr's Certificate) (To be uPloaded quarterlY) To, The M, K. Builders (Prop. Mr. Om Prakash Yadav), 3, Rajlakshmi Society, Old Saikheda Road, Deshmukh Bhavan, Durga Mata Mandir, Nashik - 422 101. (Certificate No 1 for the quarter ending 31't March' 2019) sub|ect:certificateforqua|ityofmateria|susedandqua|ityofconstructionandworkmanshipfor theWorkoflNo.ofBui|ding(s)/0Wings(s)ofthe-Phaseoftheprojectsituatedonthep|otbearing €,€-+q4=s--ale-/Surveyt'lo./sinelplet--ne-91/2'demarcatedbyitsboundaries(latitudeand |ongitudeoftheendpoints)gMetreRoadtotheNorth,gMetreRoadtotheSouth,18M.D.P.Road totheEast,PlotNo.l0CTSNolT3ltotheWest'ofDivisionNashik'VillageNashik'TalukaNashik 594 17 sq mtrs' area being developed by M K Builders ,District Nashik, PIN 422 101, admeasuring (Prop. Mr.Om Prakash Yadav) Reference: MahaRERA Registration Number- P51600019017 Sir, of this real estate project' l/ \{€- have undertaken an assignment of supervision 1, Our ResPonsibilitY: - per the approved plan To carry out the work in accordance with the development permission and as or in the and submit certificate of supervision of work and to carry out material testing in-situ quality of work and authorized laboratory and to ensure 1, Material Testing:- in the construction' checks on the basic materials' used l/rve, have applied following mandatory i. cement- settin8 time' compressive strength etc as per lS code It has been tested for its fineness' soundness' standards and its results are or as per other relevant ls/gs/NBC code, or as per industry 3535:19g6 within the Permissible limits' ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 2430L7986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per lS 5454:1978 or as per other relevant lS/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete /Ready-Mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per lS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of other materials other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittinSs etc. (List out all items) used in this project conform to relevant l5/BS/NBC code or as per standards laid down by the Industry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certifl/ that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - Works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electricalengineer and its records has been maintained The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards 4. Structural engineer: - Promoters has engaged structural engineer Mr. sunil Patel having Licenses No. 135 (N M C) having office no: 7, Wayag, Near Rajlakshmi Hall, Dhongade Mala, Dattamandir Road, Nashik Road, Nashik - 422 101 cell no 9823059201 The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per ls 7o262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5, Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other orovision of law 6. please specify materials or any other item of work which was not conforming tothe standard specifications and which was not rejected. - NIL - Yours Faithfully, 0r,."J" v Signature of Engineer (Site Supervisorl Name: Abhishek Yadav License no.(if anY)---- Phone no.9867045908 Place: Nashik Date: 05/04/2OI9