Samartha Constro Consultants LLP Shop No. 02,Virchakra Apartment SAMARTHA COVSTRO CONSUTANIS LLP Tagore Nagar, Nashik - 422006 samarthaconstroconsultants@gmail.com FORM-2A [See Regulation 3A.] ENGINEERS'S CERTIFICATE FOR QUALITY ASSURANCE (Site Supervisor's Certificate) (To be submitted at the end of Financial Year) Date: 09-06-2026 To, The Godrej Properties Limited Vikhroli, Kurla, Mumbai Suburban, 400079 Quality Assurance Certificate (Certificate No. GSTIQC/01 for the Year Ending March 2026) Subject: Certificate for quality of materials used and quality of Construction and workmanship of the work of Godrei Sky Terraces having MahaRERA Registration Number P51800053882 being developed by Godrej Properties Limited Sir, I We Samartha Constro Consultants LLP have undertaken an assignment of supervision of this real estate project Our Responsibility To carry out the work in accordance with the development permission and as per the approved plan, to submit certficate of supervision of work, to carry out material testing in-situ or in an authorized laboratory as per prevailing and applicable standards, to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and / or other relevant code of practice. The details of the quality are as follows: 1. Structural Design, Stability andTesting Sr. Yes/No Remarks Parameters No. Whether soil investigations of the site has been 1 Conducted before the structural design and soil Yes parameters have been acCounted for in the structural design/drawings? Whether Structural Engineer has been appointed for Name: Majid Hashmi License No: STRWI219 the project? Yes 2 Mobile: +91 9505888871 E-mail: majid.hashmi@kmhengineering.com book and Concrete Pouring sheet, Rolling Whether the inspection registers, site order at the site margin register, cube register are 3 quality control test registers are maintained Yes maintained and endorse by properly and endorsed by the Engineer-in- Charge? respective quality in charge at site CTM for Concrete Testing, Core Yes cutter for Soil, Water testing kit for Whether testing facilities to check quality of material is water test, Seive Analysis for Soil are available site? available at Site Page 1 of 4 Samartha Constro Consultants LLP Shop No. 02,Virchakra Apartment SAMARTHA CONSTRO CONSULTANTS LP Tagore Nagar, Nashik - 422006 samarthaconstroconsultants@gmail.com Sr. Parameters No. Yes/NoRemarks Whether the statuary provisions for disaster resistancelearthquake resistant design have been Yes incorporated, especially in case of multistoried construction? Has suitable cognizance been taken on demarcated flood lines and appropriate precautions taken for Yes 6 protecting the site from flooding considering local flooding issues? 2. Input Materials Sr. Parameters Yes/No Remarks No. Whether the following building materials confirm to 1 relevant lS/BS/NBC Code, or as per Industry Standards? If yes, provide details: IS 12269:2013, IS 10262:2019, IS (a) Cement, concrete and coarse aggregate Yes 383:2016, (b) Steel and its alloys Yes IS 1786:2023, IS 13920:2016 (c) Electrical wire, fittings and accessories Yes IS 14768:2000 (d) Plumbing and sanitary fittings Yes IS 2064 Building construction materials are Whether regular tests of materials and construction being tested at NABL accredited labs 2 products are being done from accredited labs also? If Yes like Bureau Veritas, GVM Test yes, details of such labs House,TCR, Durocrete, etc. Whether manufacturer test certificate for cement, steel, 3 pipes etc. have been obtained and whether supply Yes records are being maintained? Whether suitable water is being used for 4 construction? Ground water tested as per IS )What is the source of water? Yes 456:2016 for construction water. (ΓΌ) Has water been tested and approved by Engineer Yes in-Charge before construction? (ii) Has water been tested subsequently as per Yes requirement? Page 2 of 4 Samartha ConstroConsultants LLP Shop No. 02, Virchakra Apartment Tagore Nagar, Nashik - 422006 SAMARTHA 0OVSTRO CONSULTANIS UP samarthaconstroconsultants@gmail.com 3.Quality of Workmanship Parameters Yes/No Remarks Sr. No. Whether works of all the electrical wiringlconnections/lift installation/other electrical installations have been Allthe electrical works are carried out carried out under authorized/registered electrical Yes 1 by the authorized engineer engineer and whether records of the same has been maintained? Whether allrelated works of plumbing & sanitary including installation of water supply systems, drainage Allthe plumbing installation works are systems, sewage systems, sinks, toilets etc. have been Yes 2 carried out under authorized/registered carried out by authorized contractors plumbers/sanitary contractors and whether records of the same has been maintained? Whether allthe work is being carried out under supervision of experienced and skilled professional? Further, whether the workmanship and quality is Yes 3 satisfactory and up to the mark and the work is within the acceptable and permissible limits of deviations as per relevant Code of Practice? Whether remedial measures are undertaken to prevent Active waterproofing in being done dampness and leakages? If yes, provide details Yes from positive side with materials tested and approved at third-party labs. Whether safety precautions are undertaken during Yes 5 construction activities for all type of workers? 4. Miscellaneous Parameters Yes/No Remarks Sr. No. Whether third party quality inspection is being carried Quarterly third-party quality audits by out on site during/after completion of the works? If yes, Yes Bureau Veritas. provide details. Whether anti-termite treatment has been undertaken Yes 2 for the soil? Under the supervision of MEP Whether fire-fighting arrangements has been Yes 3 undertaken under supervision of fire consultant? consultant Allthe signages have been installed as Whether proper signage have been installed on Yes per the safety standards 4 site/completed building as per requirement? Smog guns, protective nets, metal barricades, AQl monitoring machines, Whether precautions are undertaken to avoid air Yes etc. are being used to control air pollution during construction? Please specify. pollution. Whether records of all test reports/results have been the properly kept in the prescribed formats and whether Yes 6 same are available at site for viewing by allottees and to be handed over to the association of allottees? Whether all relevant records including sanctioned building plans, utility drawings, various test 7 reports/results have been properly kept in the Yes prescribed formats to be handed over to the association of allottees? has Any innovative/cost effective/green technology efficiency? Yes Solar power energy, efficient HVAC been used for improving qualitylenergy systems, energy efficient lighting. Please specify. locally sourced building materials, etc. Page 3 of 4 Samartha Constro Consultants LLP Shop No. 02, Virchakra Apartment SAMARTHA CONSTRO CONSULTANIS UP Tagore Nagar, Nashik - 422006 samarthaconstroconsultants@gmail.com Yours Faithfully Signature of Engineer (Site Supervisor) Name: Abhishek M. Loya Qualification: M. Tech License No. (if any): STATE/RI2025/APL22589 Phone No: 9130764811 Place: Nashik Agreed and accepted by Signatdra of Promoter Name: Godrej Properties Limited Date:09-06-2026 Dnge 4 of 4