MAYURESH JADHAV D.C.M. CruIL ENGINEER A/3O4, Sai Kripa, Charkop Sector-8, Kandivali West, Mumbai - 400067 FORM.2A ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE To Pranav Constructions Private Limited 1001, 1Oth Floor, DLH Park, S. V. Road Near MTNL, Goregaon West Mumbai - 400062 Qua lity Assu rance Certificate (For the quarter ending 30th JUNE 2024) Subject: Certificate for quality of materials used and quality of Construction and workmanship for the Work of the project 'Redevelopment of Samrat Co-operatrve Housing Society Limited' land bearing final Plot No. 28 of TPS Santacruz lV, Santacruz No. ll, bearing C.T.S. No. G-92, of Village Bandra -G, admeasuring in the aggregate as 1028 square meters, as per Final Plot TPS Santacruz No. ll, situated at Juhu Road, Santacruz (West), Mumbai -400 054 in the Registration District and Sub-District of Mumbai City and Mumbai Suburban, being bounded as On or towards the EAST: By Final Plot No.34D of TPS Santacruz No l'1 , On or towards the WEST: By Final Plot No. 29 of TPS Santacruz No ll, On or towards the NORTH: By 60 Feet Juhu Road as mentioned in TP and 90 Feet Juhu Road as per DP, On or towards the SOUTH. By Final Plot No. 35-36 of TPS Santacruz No. ll as mentioned in the Property Card being re-developed by Pranav Constructions Private Limited. Reference: MAHARERA Registration Number- P51800053827 Dear Sir l, Mayuresh Jadhav have undertaken an assignment of supervision of this real estate project Our Responsibility: To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision work and to carry out material testing in-site or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. l. Material Testing: I have applied for the following mandatory checks on the basic materials that is being used in the construction. MAYURESH JADHAV D.C.M. CTVIL ENGINEER A/3O4, Sai Kripa, Charkop Sector-8, Kandivali West, Mumbai - 400067 t. Cement It has been tested for its fineness, initial and final setting time, and normal consistency test, etc. as per lS code 403'l Part I 1996, lS code 4031 Part V of 1988 lS code 4031 Part lV 1988, as per industry standard and its results are within the permissible limits. lt. Coarse aggregate 10mm Metal -1-Sieve Analysis Test, 20mm Metal -1-Sieve Analysis Test, it has been tested for gradation, deleterious materials, clay lumps as per lS code 383.1970, lS code 383: 1970 2386 PART I, lS 2386 PART lll, lS 2386 PART lV, and lS code 383:2016 as per industry standards and its results are within the permissible limits. iii. Brick/s/BlocUs: Bricks- Bricks have been tested for compressive strength as per lS code 3495 Part l:1992, size of bricks as per lS Code 1077:1992, determination of water absorption as per lS 3495 Part ll:'1992, determination of efflorescence as per lS 3495 Part 111.1992, etc. AAC Blocks- AAC blocks have been tested for water absorption, compressive strength, block density, moisture content as per lS code 2185 Part 1-2005, lS code 2185 Part 1- 1984 Concrete/ Ready Mix Concrete It has been tested for compressive strength, calibration, workability, slump as per lS Code 456:2000 and lS code 4926:2003,1S code 516, lS code 1199: 2018 as per industry standards and its results are within the permissible limits. Structutal / Steel for Concrete. It has been tested as per lS code: 1786. 2008, as per industry standards for tensile strength, elongation, rolling margin, yield, strength, bend, re-bend, gauge length etc. and its results are within the permissible limits. Testing of other materials. Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. used in this project conform to relevant lS/BS/NBC code or as per standards laid down by the industry for particular materials. 2. Workmanship: - I hereby certify that the work has been carried out under my supervision. I further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per the relevant code of practice. Y MAYURESH JADHAV D.C.M. CTVIL ENGINEER A/3O4, Sai Kripa, Charkop Sector-8, Kandivali West, Mumbai - 400067 3. Electrical Materials and Workmanship: - I hereby certify that the work of all the electrical wirings/ connections / lift installations/ other electrical installations have been carried out under authorized/ registered electrical engineer and records have been maintained. The materials used conform to the relevant lS/ B.S/ National Building codes or as per lndustry standards. 4. Structural Enqineer: - The Promoters have appointed Structural Engineers viz. M/s Shanghvi and Associates Consultants Private Limited Having License No. STR/S/193 having Office No. 02226144832, Mobile No. 9867300054. The Structural design of the building in this pro.iect has been done under supervision. The formwork and concrete mix design has been done as per lS Code 10262.2009 or as per other relevant codes as applicable. The periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5.ECty.allgn of Rec-qCS.: - The record of all test results of this project have been properly kept in the prescribed format and will be preserved at least up to the Defect Liability Period or for the period as required by any other provtsions of law. 6. Please specify materials or any other items of work which did not conform to the standard specifications, and which were not relected. - Not Applicable. We are using all materials as per lS specifications or as per lndustry standards. Yours Faithfully Y Mayuresh Jadhav (Engineer) Phone No: 976981457 1 Dale: 15.07 .2024