;{ ADffYA D MflHTA (B.E.cMr) IJcENCE PLUMBER *ND UcENCE sITE supg8VlsouR B/2O CII.fiNDSIKA T.PPARTMENT SIIAITK^IR UTltIf,. T*TOTVTU (rrEST) [IUMBAI.4OOO6? FORM-2A [See Reguhtion 3A.l ENGINEERS'S CERTIFICATE FOR QUALITY ASSURANCE (S'rte Supervisor's Certificate) (To be submitted at the end d Financial Year) Date: 2{ , o).}o21o, To, The PRANAV CONSTRUCTIONS LIMITED Borivali, Borivali, Mumbai Suburban, 400062 Quality Assurance Gertificate (Cefficate No. ......................for the year Enoing 3l:.? 2: J,p-ZQ...l Subrect : Certificate for quality of materials used and quality of Construction and workmanship ol the work of REDEVELOPMENT OF SHINING STAR CHSL having MahaRERA Registration Number P51800053810 being developed by PRANAV CONSTRUCTIONS Lltf,lTED Sir, l/We ........... have undertaken an assignment of supervision of this real estate proiect Our Responsibility To carry out the wolk in accordance with the development permission and as per the approved plan, to submit celtiticate ol supervision of work, to carry out materialteting in-situ or in an authorized laboratory as per prevailing and applicable standards, to ensure qualiU of work and uorkmanship as per prescribed specifications, and as per NBC and / or other relevant code of practice. The details of the quality are as follows : 1. Structural Design, Stability and Testing Sr. No. Parameters Yes/ilo Remarks 1 Whether soil investigations of the site has been Yes conducted before the structuraldesign and soil parameters have been accounted lor in the S!4Lq.laL des ign/d rawi ngs ? 2 Whether StructuralEngineer has been appointed for Yes Name: SACPL the proiea? License No: STR/S/193 Mobile: 9987720006 E-mail: keshavqadkar@ sacpt.co 3 Whether the inspection registers, site order book Yes and quality control test registers are maintained at the siteproperly and endorsed by the Engineer-in- ciarse? 4 Whether testing facilities to check quality of material Yes To ensure the highest level of precision, is available at site? is conduaed at ffi-8;ilH1"Y',"':": (L C irpervisor) Page 1 of3 (Lic 1.tBgi_qs_J,) Sr.llo. Paramaers Yes/Irlo Remarks t 5 Whether the statuary provisions for disaster Yes resistancer/earthquake resistant design have been incorporated, specially in case of multi-storeyed construction? 6 Has suitable cognizance been taken on demarcated Yes flood lines and appropriate precautions taken for protecting the site from flooding considering local floodino issues? 2. lnput ltlaterials Sr. No. Paranreters Yes/No Remarks 1 Whether the following building materials confirm to Yes relevant IS/BS/NBC Code, or as per lndustry Standards? ll ves. orovide details: (a) Cement. concrete and coarse aooreoate Yes As per lS 45&2000 (b) Steel and its alloys Yes As per lS-178G2008 (c) Electrical wire. fittinqs and accessories Yes (d) Plumbino and sanitarv fiftinos Yes 2 Whether regular tests of materials and construction Yes STRUCTWEL LAB PVT. LTD. producls are being done lrom accredited labs also? lf ves. details of such labs 3 Whether manufaclurer test certificate for cement, Yes steel, pipes etc. have been obtained and whether suooly records are beinq maintained? 4 Whether suitable water is being used for Yes construction? (i) What is the source of water? Yes BMC Lineffanker Water (ii) Has water been tested and approved by Yes Enoineer-in-Charoe before construction? (iii) Has water been tested subsequently as per Yes reouirement? 3. Quality of Workmanship Sr. No. Parameters Yesfio Remarks 1 Whether works of allthe elearical Yes wiring/connections/lift installation/other electrical installations have been carried out under aulhorizedl registered electrica I en gineer a nd whether recoi'ds of the same has Seen maintalned? 2 Whether all related works of plumbing & sanitary Yes' including installation of water supply systems, drainage systems, sewage systems, sinks, toilets etc. have been carried out under authorizedregistered plumbers/sanitary contractors and whether records of the sarne has been maintained? 3 Whether allthe work is being carried out under Yes supervision of experienced and skilled professional? Further, whether the workmanship and quality is satisfactory and up to the mark and the work is within the acceptable and permissible limits_of dp-viations as oer relevant Code of Practice? AditYa ervisor) (Licence ite SutP Page 2 of 3 giss-I") (Licer'ce No.Mi48 Sr. No. Parameters Yes/Irlo Remarks 4 Whether remedialmeasures are undertaken to Yes We do DPC before start the brick work or prevent dampness and leakages? lf yes, provide block work details 5 Whether safety precautions are undefiaken during Yes construciion activities for all Wpe of workers? 4. iiiscellaneous Sr.l{o. Parameters Yesrllo No 1 Whether third party quality inspection is being Yes carried out on site during/after completion of ihe works? lf yes, provide details. 2 Whether anti-termite treatment has been undertaken Yes for the soil? 3 Whether fire-fighting arrangements has been Yes undertaken under supervision of fire consultant? 4 Whether proper signages have been installed on Yes sit€/completed buildinq as per requirement? 5 Whether precautions are undertaken to avoid air Yes We follow all rule as per AQI tlorms pqllutiqn during construction? Please specifu . 6 Whether records of all test reports/results have been Yes properly kept in the prescribed formats and whether the same are available at site for viewino bv allottees and to be handed over to the aEs