MAYURESH JADHAV D.C.M. CTVIL ENGINEER A/3O4, Sai Kripa, Charkop Sector-8, Kandivali West, Mumbai - 4o00,67 FORM-2A ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE To Pranav Constructions Private Limited 1001 , 1Oth Floor, DLH Park, S. V. Road Near MTNL, Goregaon West Mumbai - 400062 Qualitv A ssurance Certificate (For the quarter ending 30th JUNE 2024) subject: certificate for quality of materials used and quality of construction and workmanship for the work of 4 wings/Buildings of the project 'Redevelopment of shining star co-operative Housing society Limited' of the project situated on sub plot Nos. 79, g0 and g1 of revised layout approved by Town Planning Dept from Final plot Nos. 'lg & 19 Tps vl Sanlacruz, c.T.s. No. 1610/8 admeasuring 2853 sq. yards i.e. 23g5.5 sq mts or thereabouts of Revenue Village and City Survey Vile Parle (West), Taluka Andheri in the Registration District and Sub- District of Mumbai Suburban, in Brihan Mumbai Mahanagarpalika HA/V ward and lying, being and situate at 79, 80, 81, Relief Road, Daulat Nagar, santacruz (West), Mumbai 400 054, and - Bounded As Follows: Towards North. By A creek And Beyond rhat By Juhu Aerodrome of Village of vile Parle (w) Towards East: By ptot Nos. 84 To 86 of Viilage of vite parle (W Towards west: By Public Road of village of Vile parle (w) Towards South: By plot Nos. 82 And 83 of village of Vile Parle (w) as Mentioned ln the property card being re-developed by Pranav Constructions Private Limited Reference: MAHARERA Registration Number- psl 8OOO53Bl O Dear Sir l, Mayuresh Jadhav have undertaken an assignment of supervision of this real estate project. Our Responsibility: To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision work and to carry out material testing tn-site or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. t. Material Testing: I have applied for the following mandatory checks on the basic materials that is being used in the construction. V MAYURESH JADHAV D.C.M. CTVIL ENGINEER A/3O4, Sai Kripa, Charkop Sector-8, Kandivali West, Mumbai - 400067 Cement It has been tested for its fineness, initial and final setting time, and normal consistency test, etc. as per lS code 4031 Part I 1996, lS code 4031 Part V of 1988 lS code 403'l Part lV 1988, as per industry standard and its results are within the permissible limits. ii Coarse aggregate lOmm Metal -1-Sieve Analysis Test, 20mm Metal -'l-Sieve Analysis Test, it has been tested for gradation, deleterious materials, clay lumps as per lS code 383:1970, lS code 383.1970 2386 PART l, lS 2386 PART lll, lS 2386 PART lV, and lS code 383:20'16 as per industry standards and its results are within the permissible limits. iii BricUs/BlocUs: Bricks- Bricks have been tested for compresstve strength as per lS code 3495 Part l:1992, size of bricks as per lS Code '1077:1992, determination of water absorption as per lS 3495 Part ll:1992, determination of efflorescence as per lS 3495 Part lll:1992, etc. AAC Blocks- AAC blocks have been tested for water absorption, compressive strength, block density, moisture content as per lS code 2185 Part 1-2005' lS code 2185 Part 1-1984 Concrete/ Ready Mix Concrete It has been tested for compressive strength, calibration, workability, slump as per lS Code 456:2000 and lS code 4926.2003, lS code 516, lS code 1199: 2018 as per industry standards and its results are within the permissible limits. Structutal / Steel for Concrete- It has been tested as per lS code: 1786: 2008, as per industry standards for tensile strength, elongation, rolling margin, yield, strength, bend, re-bend, gauge length etc. and its results are within the permissible limits. Testing of other materials: Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary flttings etc. used an this project conform to relevant lS/BS/NBC code or as per standards laid down by the industry for particular materials. 2. Workm anshio: - I hereby certify that the work has been carried out under my supervision. I further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per the relevant code of practice' MAYURESH JADHAV D.C.M. CTVIL ENGINEER A/3O4, Sai Kripa, Charkop Sector-8, Kandivali West, Mumbai - 400067 3. Electrical Materials and Workmanshi I hereby certify that the work of all the electrical wirings/ connections / lift installations/ other electrical installations have been carried out under authorized/ registered electrical engineer and records have been maintained. The materials used conform to the relevant lS/ B.S/ National Building codes or as per lndustry standards. 4. Structural Enqineer: - The Promoters have appointed Structural Engineers viz. M/s Shanghvi and Associates Consultants Private Limited Having License No. STR/S/193 having Office No. 02226144832, Mobile No. 9867300054. The Structural design of the building in this project has been done under supervision. The formwork and concrete mix desrgn has been done as per lS Code 10262:2009 or as per other relevant codes as applicable. The periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of Records: - The record of all test results of this project have been properly kept in the prescribed format and will be preserved at least up to the Defect Liability Period or for the period as required by any other provisions of law. 6. Please specrfy materials or any other items of work which did not conform to the standard specifications, and which were nol rejected. - Not Applicable. We are using all materials as per lS specificalions or as per lndustry standards. Yours Faithfully Y Mayuresh Jadhav (Engineer) Phone No. 9769874571 Dale: 15.07 .2024