FORM -2A (See MahaRERAOrder no 5 of 2018) ENGINEER CERTIFICATE FOR QUALITY ASSURANCE (Site supervisor's Certificate) (To be Submitted at the end of the Financial Year) Date: - 31st March 2024 To, Integrated Spaces Limited DWing, Karma Sankalp, Corner of 6th and 7th Road of Rajawadi, Ghatkopar East, Mumbai 400077. Quality Assurance Certificate FY 23-24 Subject: Certificate of Percentage of Completion of Construction Work of one Building, comprising of 2 Wings i.e. A and B of the Project named "Integrated Kavya" [MahaRERA Registration Number P51800052486] situated on the Plot bearing C.T.S. No. 638/1 of village Ambivali, at J.P. Road, Andheri (West), Mumbai K/W Ward District Mumbai, State Maharashtra PIN 400058, admeasuring 3078.00 sq.mts. area being developed by Integrated Spaces Limited. Ref: MahaRERA Registration Number P51800052486 Sir, IPradeep Thorat have undertaken assignment of supervision of the real estate project 1. Our Responsibility To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. 1. Material Testing /we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement It has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant I5/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/ Ready-mix Concrete It has been tested for compressive strength for various periods as per 1S 456:2000 and IS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steelfor concrete It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials - Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the Industry for a particular material. 2. Workmanship I/We hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permission limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - works of allthe electrical wiring/ connections Ilift installation Iother electrical installations have been carried out under authorized /registered electrical engineer and its records has % been maintained. The materials used conform to the relevant 1.5/ B.S/ National Building codes or as per industry standards. 4. Structural Engineer Promoters has engaged structural engineer Mr. Bhushan NSanghavi Having Licenses No. STR/S/112 Having Office No. 022 26153637/26133804 Cell No. 9821882057. The structural design of building in This project has been done under his supervision. The formwork and concrete mix design has been done as per IS 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records Record of all test results of This project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period of for the period as required by any other provision of law. 6. Please specify deviation in quality of material or any other item of work which were not conforming to the specifications as mentioned in agreement of sale Yours Faithfully, Signature of Engineer' (Site Supervisor) Name: Pradeep Thorat License No. (if any) ( Phone No: 9930453104 Place: Mumbai Agreed and accepted by: SPACE oMUMBAI Signature of promoter Name: Date: