Form 2A (CMality Assurance Certificate No 2) Date: 23.08.2023 To, JPV Realtors Pvt. Ltd. 7th & 8 th Floor, Jet Prime, Suren Road, Near WEH Metro Station, Andheri - Kurla Road, Andheri (East), M umbai-400093. Subject: Certificate of Cost Incurred fo r O='/Elopment and COlstruction of building Called as Pratap Oasis situated on CTS No. 307/86 & CTS NO. 3(7/8-:', demarcated by its boundaries CTS No . 307/82 & CTS No. 307/83 to the North, CTS No. 307/93 & CT:; iN J . 307/94 to the S,::;utr, Municipal Road to the East and West, of Village Valnai, Ta luka - Borivali, D,i stric: Mumtai, PincodE 400064, admeasuring cumulatively 980.60 Sq. Mt area being developed by JPV Realtor~ Pv:. Ltd. Reference: MahaRERA Registration NumbEr "P51800023003" Sir, I, Shri Jayesh Vyas have undertaken an a:ssi~lm=nt of superviskm of this real estate project. My Responsibility: To carry out the work in accordance with tine development permis~ion and as per the approved plan and submit certificate of supervision ·)f wcrk end to ,:arry out mat eri031 testing in-situ or in the authorized laboratory and to ensure quality of work and ensure the following 1. Material Testing I have applied following mandatory checks on tle b3sic materials, used in the construction. i. Cement: It has been tested for its finenEss, 50undness, settilg :ine, compressive strength etc. as per IS code 3535:1986 or as per other relevart 1~'851NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse Aggregate: It has been tested, foc rdei€ t erious materials, day lumps, crushing value, impact value as per IS 243011986 or as per othe ' releya H I~/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/Blocks: They have been tested fo r water absorption, :rush ng strength etc. as per IS 5454:1978 or as per other relevant IS/85/NBC code or as: per industry standards and its results are within perrnissible limits. .: ::~~~J;:5§::: :~ :'., :I ~;~;i~'::: i' '.,:'-« ~,:~)."~';: /:. ~: l I " ·" I"" ' '''of , • . •• .' . ,.~ .. '-" . .... ..... . . . : , iv. Concrete/Ready-Mix Concrete: It has beel1 tested for compressive strength for various periods as per 15456:2000 and IS 1199 or as per other relevar,t IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for Concrete: It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, e' ongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other Materials: Other materials ike sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a partiOJlar material. 2. Workmanship I hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and Workmanship Works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant IS/ 8.5/ National 3uilding codes or as per industry standards. 4. Structural Engineer Promoters has engaged structural engineer Shri Hiren Tanna having License No STR/T/35 having office no 022-28929500 & Cell no 022-28929600 The structural design of buildings ,in this proje:t has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design have been done as per Is 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFCY have been kept on record. 5. Preservation of Records Record of all test results of this project havE: been properly kept in the prescribed formats and will be preserved at least up to the defect liability periDd or for the period as required by any other provision of law Please specify materials or any other item of w,]rk which were not conforming to the standard specifications and which were not rejected. Yours Faithfully, Sig~ Engineer (Site Supervisor) Name: Shri Jayesh Vyas License No: NA Contact No: 9867121290 Place: Mumbai