Sufias S. Patav 8-302. Jagruli CHS. Near :Valio1w/ School. Mcmvel Puc/a Road. Vita,. (East). Taluka Vasai. Districl . Palglwr. Pif1code - ..J01303 ------------------------------------'---------­ ----------------------------- FORM-2A [ See MahaRERA order No.5 of 2018] ENGINEER'S CERTJFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, Flying Earth LLP Office No. 1& 2, Parmar C.H.S Paranjape B Scheme Road No 1 Vile Parle East, Mumbai - 400057 Quality Assurance Certificate (Certificate No.5 for the quarter ending 31.12.2019) Subje~t : Certificate for quality of materials used and quality of Construction and workmanship for the Work of 1 No. of Building(s)! of the project situated on the plot bearing C. S. No.lC.T.S. No.1 Survey No.lFinal plot NO.264,264! 1 to 8, demarcated by its boundaries (latitude and longitude of the end points)19 6 29.60N-72 50 56.65Eto the North19 6 29.65N-72.50 57.39E to the South19 6 28 .69N-72 50 57.42E to the East 19 6 28.60N-72 50 56.7'1 E to the West of Division KlE village Vile Parle East taluka Andheri District Mumbai Subarban ,Vile Parle East PIN 400057 · admeasuring 639.9 sq.mtrs. area being developed by Flying Earth LLP Reference: MahaRERA Registration Number- P51800020800 Sir, I Suhas S Palav have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testing: IIwe, have applied following mandatory checks on the basic materials, used in the construction. I. Cement- It has been tested for its fineness, soundness, setting time, compressive strength as per IS code 3535: 1986 or as per other relevant IS/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 243011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks They have been tested for water absorption, crushing strength as per IS 5454:1978 or as per other relevant IS/85/NBC code or as per industry standards and results are within permissible limits. iVa Concrete/Ready-mix Concrete It has been tested for compressive strength for various periods as per 15 456:2000 and IS 1199 or as other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete It has been tested as per IS 2062:2011 or as per other relevant ISIBSINBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor fixtures and {fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant ISIBSINBC code or as per'standards laid down by the industry for a particular material. 2. Workmanship: II we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. • Sufias S. Pa/tzy B-302, Jagruli CHS. Neal' Natiollal School, Manvel Pada Road, Viral' (East). Taluka Vasai, District Pa/ghar, Pillcode - 401303 -_._------------------------_ ...----------------------------------------------------­ 3. Electrical Materials and workmanship: works of all the electrical wiring/connectionsllift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant I.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: Promoters has engaged structural engineer Mr.R.O Oeshpande having Licenses No. Reg.No: STRlO-64 of 2018-21 having office No 24216215 The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying pee for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per Is 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept onrecord. 5. Preservation of records: Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. - NIL Yours Faithfully, ~y Suhas S.Palav (Site Supervisor) License No. : P/512/SS - " Phone No.: 9096813518 Place:Mumbai