GIRTSHKUMAR V. A/33,Yogi N agar,Flat GUPTA No.OO3 ,Ekar Roa4Borivali lwest),Mumbai-4 00 091 FORM - 24 [See MahaRERA Order n of 2otsl ENGINEER'S CERNFICATE FOR QUATIry ASSUMNCE (site supervisot s certlficate) 03.O2.2020 To, Sunil T,(ukreja , Tolaram &Co. Laalasis plot No,2t9. tls Roa4Chembur Mumbal4IOOTl euality Assurance Cenificate (Cenificate No. 1 for the quarter ending_Dec-19) Subject: Certificate for quality of materials r o'"lity of construction and workmanship for the work of *rr,""' 'no situated on *," prot u"",inJ c.;I:1.:;:1T.XlliiTjI,,:H,; No.465/A,46Slt to 20, 465/8 demarcated by its boundaries (latftude and longitude of the end points) Khot Road to the ;;;;;; Apartment Existing to the South to the East CfS.No. +O+A to tie Wert of Division Bhandup village taluka Kurla District Mu.O"l SrUrrO"n pffl 400 078 admeasuring 2632.40 s( l'mtrs' area being developed by [Promote/s Name Mr.Sunil Tolaram Kukreja, partner ofTolaram & Co. Reference MahaRERA Registration Number_ p 5I8OOO2O817 Sir, lllve GirishKumar Gupta have undertaken an assignment of supervision of this real estate project. GIRISHKUMAR V. GUPTA A,/33,Yogi Nagar,Flat No.003,Eksar Road,Borivali (West),Mumbai -4m 091 l. Our Responsibility:- To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. 2. Material Testingi l/We, have applied following mandatory checks on the basis materials, used in the construction. xIt Cement- It has been tested for its fitness, soundnest setting time, compressive strength etc. as per lS Code 3535:1986 or as per other relevant IS/BS/NBC code, or as per industry standards and its results are within the permissible limits. xtv Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 2430:1986 or as per other relevant IS/BS/ NBC code, or as per industry standards and its results are within the permissible limits. Brick,/ block - They have been tested for water absorption, crushing strength etc. as per lS 5454:1978 or as per other relevant |S/BS/ NBC code, or as per industry standards and its results are within the permissible limits. xvi. Concrete / Ready- mix concrete - It has been tested for compressive strength for various periods as per lS 456:2000 and lS 1199 or as per other relevant |S/BS/ NBC code, or as per industry standards and its results are within the permissible limits, xvl. Steel for concrete - It has been tested as per lS 2062:20!l or as per other relevant |S,/BS/ NBC code, or as per industry standards for tensile strength, elongation and gauge len8th etc. and its results are within the permissible limits. GIRISHKUMAR V. GUPTA Ai/33,Yogi Nagar,Flat No.0O3,Eksar Road,Borivali (West),Mumbai -/tOO 091 xviil. Testing of Other materials - Other materials like sand, crushed sand, floor tiles, fixtures ard fittings, pipes and sanitary fittings etc. (List out all ttems) used in thlg proiect conform to relevant IS/BS/ NBC code, or as per industry standLrds laid down by the lndustry for a particular material. 3. Workmanship:- lfA/e hereby certify that work has been carried out under our supervislon. We further certify that workmanship and quality is satisfastory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 4. Electrical Materials and workmanship:. Works of all the electrical wiring/connectlons/lift instellatlon/other alectrical installations have been carried out under authorized / reglstered alectrical englneer and its records has been maintained. The materials used cooform to the relevant LS/B.S/ National Building Code, or as per industry standards. 5. Structural Engineer:. Promoters has engaged structural engineer Mr. Hiten MaHmtura, Reg.Address: Unique House,3d Floor,S.A.Brelvi Road,FooMumbai{Oo OO1 having Licenses no. STR/M/63.having office Phone No.02243685(n0 cell no.9820088003 The structural design of buildings in this proiect has been done urder his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per lS 10252:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABIUW and SAFETY have been kept on record. GIRISHKUMAR V. GUPTA A,/33,Yoti Nagar,Flat No.oo3,Ekar Road,Boriyall (West),Mumbat 4(x) 091 6. Preservatlon of recordsi Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liabllity period or for the periods as required by any other provision of law. 7. Please specify materials or any other item of work which were not conforming to the standard specificatlons and which were not rejected. Yours ithful tud L:.i a I of gineer (Site Supervisorl Name : Girlsh mar V.Gupta License No. (G/1it4lSSl) Phone no. 9323157531 Place:Mumbai