FORM-2A [See MahaRERA order no. of 2018] ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, The Shree Siddhvinayak Classic Construction Pvt Ltd '10, "l't Floor, Ruparel lRlS, Nair Mahal, Senapati Bapat Marg, Mahim West, Mumbai-400016 Qualitv Assurance Certifi cate (Certificate no. 001 for the quarter ending December 2019) Subject : Certificate for quality of materials used and quality of Construction and workmanship for the Work of 1 No. of Building/ 2 Wings of the project situated on the plot bearing C. S. No./C.T.S. No./ Survey No./Final plot no.6(pt) demarcated by its boundaries Adjoining Nalla to the North Existing Road to the South Adjoining Bldg No 89 to the East Mother Dairy Road to the West of Division - lll village - Kurla taluka - Kurla District Mumbai Suburban PIN 400024 admeasuring 931.87 sq.mtrs. area being developed by Shree Siddhivinayak Classic Constructions Pvt Ltd Reference: MahaRERA Registration Number- P51800020602 Sir, l/ We_ have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in arcordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testinq :- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressivestrength etc. as per lS code 3535:1986 oras per other relevant lsi8s/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant lS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per lS 5454:1 978 or as per other relevant |S/8S/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per lS 2062:201 1 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and {fittings, pipes and sanitary fittings etc. (List out all iiems) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - YruIta of all the electrical wiring/connections/lift installation/other electrical installations have been caried out under au$orieedkegistered electrical engineer and its records has been mainiained, The rnaterials used confon, to the relerwt l.sl B.s/ Nationar Buirding mdes or as per industry standards. -"--' 4. 8ktrc.frraat engioeer: - Promote6 te* engaged stryclyEt engineer Mr. Acfiy_ut traving Licenses no. M c G B reg. No. srR/ w10 for & uqt", ON be$alf SJV1I Consuttants LLp, haiing offie no-_ 31_2066449100. The struciliral dsign of buildings in this proiect has been done under hls supervision. Fie has checked the soil report before laying FCc for foundatisn in consuiation with soil co*suttant" rrre hen dsne as per ls 10262:2009 or as per other relevant *d"" ;"6d;caure.ronnworx ano concrete rnix deign has nu periodic cfre*s and ertificates for $TABlLllY and SAFETY have been kept on record. 5. Prrgemation of records: - pPi* Record of all test rcsutts of thjs iave been prop.erlv_keBt in the prescribed formab and will be preserved at least up to the detuct liabitity period or for ihe perioa as ieqriireo oy lny oirreiprovision oruw 6' Pleme specifu rnaterials or any other iten'r ot work whicfr nuele nst confionning to the standard specifications and which vere not rejec*ed, Place: 7115, Artbt C-B.D. Belapur, Navi idumbai- 400614. .a. :i:.