a Vijaya Consultants BUILDIT.IG CONSULTING ENGINEERS PLANNERS NEW PANOIT COTONY NASHI( a Ph (0)2574602 Mob 98220 206.,. STRUCTURAL Ema'! . ashoqamda@yah@ cN CONSULTANTS ASHOl< JAMOAR Annexure - A FORM-1 I See Regulation 3 ] CERTIFICATE (To be submitted at the time of Registration of Ongoing Project and for withdrawal of Money from Designated Account) Dale: ol / ol lco- "> To, Ratnaprabha Residency, Rajeshwar BuildeB, Tapovan Unk Road, Nasik. Subject : Certificate of Percentage of Completion of Construction Wo* "Rahaprabhaof Residency", having Maha RERA Registraton Number- P51600022701 , being developed by, Rajeshwar Builders, Tapovan Link Road, Nasik. Sir, I, Mr. Ashok Jamdar, have undertaken assignment as Engineer / Ucensed Surveyor of certifying Parentage of Completion of Construdion Work of "Ratnaprabha Residency", having l,4aha RERA Registration Number P51600022701 , being developed by, Rajeshwar Builders, Tapovan Link Road, Nasik. TABLE - A Layout i Building / Wing Number Plot No.24, S N 622129, l'idke Colony, Nashik[ to be prepared separately for each Layouv Buildinq / wing Number of the Projectl. Sr, No, Tasks / Activity - Percentage of Actual Work Done { As on date of the [1 l t 2l Certificate ) t3t 1 Exaavation 100 o/o 2 Basements I if any ] N/A 3 Podiums I if any ] N/A 4 Plinth 100 o/o 5 Stilt Floor N/A 6 slabs of Super structure 100 o/o 1 Internal walls, Internal Plaster, Floorings, Doors and 60 o/a windows within Flats/Premises B Sanitary Fittinqs within the Flat/Premises 25 o/o 9 Staircase, Lifu Wells and Lobbies at each Floor level Overhead and Underqround water Tanks 100 % 10. External Plumbing & external Plaster, elevation, completion of terraces with waterproofing of the 40 o/a Buildinq/Winq 11. Installation of Lifts, water pumps, Fire Fighting Fittings and Equipments as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions of environmenvcRz NOC, Finishing to entrance lobby/s, plinth protection, paving of areas N/A appurtenant to Building^Ving, Compound Wall and all other requirements as may be required to complete project as per specifications in aqreement of sale. Any other activities. TABLE - B Common Areas [Internal and Extemal Development Wo.ksl in respect of the Registered Phase / Project Number' S. No Common Areas and Proposed Percentage Of Details Facilities Amenities Completion 1 Internal Roads & No NA Footpaths 2 Water Supply Yes 0o/o Borewell facillty already available Local Body Water Supply will be provided as and when available. 3 Sewerage (Chamber, Yes oo/o NA Lines, Septic Tank, SI?) 4 Storm Water Drains No NA 5. Landscapinq & Tree Yes 0o/o NA Plantinq 6 Street Liqhtinq No NA 7 Community Buildings No NA 8 Treatment And Disposal No NA of Sewage And Sullage Water 9 Solid Waste Management No NA And Disposal 10 Water Conservation, Rain Yes Oo/o Rain Water water Harvestin9 Harvesting Unit will be constructed in due course of 11 Enerqy manaqement No NA 12. Fire Protection And Fire No NA SafetyRequirements 13. Electrical lvleter Room. Yes la/o Electric Meter Sub-Station, Receiving for Constructions Station purpose installed and only limited upto common Electricity meter and Allotee Electricity meter, Allotee mete6 will be installed at final finishing of work / at possession of units. 14. Others (Option to Add more) Yours Faithfully, Engineer / Licensed Surveyor Er. Ashok Jamdar License No- R.NO.- 134199 Er Ashok Jamder R,No. PELR 121 Lic No - .t 34199 Signature of Promoter. Name: