Darshan Jagdish Kankrej B.E (Civil), A.M. I.E Consulting Engineers, Building Planners \. 8421361224 Regd. No : 755 FOR.\II- 2 A [ see Maha-RERA order No.5 of 2018 ] ENGINEER'S CERTIFICATE FOR QOATITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, The Jai Padrnavati Builders, Seva Sudan, Pakhal Road, Dwarka, Nashik 422001. Quality Assurance Certificate (Certificate No. SQ/Oct/20 for the quarter ending Oct 20 - Apr 21) Subject: Certificate for quality of materials used and quality of Construction and workmanship for the Work of Padrnavishwa Dream Square Apartment No. of Building one of the Project situated on the plot bearing Survey No. 39/A/S/l Final Plot No. 15 demarcated by its boundaries ( latitude and longitude of the end points) Canal to the North 18 !VItI'Road to the South Plot No 13 & 14 to the East Adj Sr. No. 39/A/6 to the 'West of Division Nashik Village Nashik (M. Corp) Taluka Nashik District Nashik PIN 422001. admeasuring 630.04 sq.mts. area being developed by Jai Padmavati Builders. Reference: :\1ahaRERA Registration ]';0. PS16oo022190 Sir, I / \,\TeDarshan Jagdish Kankrej have undertaken an assignment of supervision of this real estate project. OUI'Responsibility: To carry out the work in accordance with the development approved permission and as plan and submit certificate of supervision of work ancl to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. Siddhi Pooja Regency Backside Of Vihar Hotel Old Gangapur Naka Nashik 1. Material Testing: J / We, have applied following mandatory checks on the basic materials, used in the construction. i) Cement - It has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant IS/85/NBC code, or per industry standards and its results are within the permissible limits. ii) Coarse Aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. Iii) Bricks/ mocks - They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/85/NBC code or as per industry standards and its results are 'within permissible limits. IV) Concrete / Ready-mix Concrete - It has been tested for conipressix e strength for various periods as 456:2000 and IS 1199 or as per other relevant IS/liS/NBC codes, as per industry standards and its results are within permissible limits. v) Steel for Concrete - It bas been tested as code or as per IS 2062:2011 or as per other relevant Is/Bs/NBC per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi) Testing of Other 1\1aterials - Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fillings etc. (List out all items) used in this project conform to relevant 1S/ES/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship: - I / we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and lip to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and Workmanship: - Works of all the electrical wiring/ connections / lift installation electrical installations have been carried out under authorized /registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structural Engineer: - Promoters has engaged structural engineer Mr. Darshan Jagdish Kankrej having Licenses No. 755 having Office No. +91 8421361224 Cell No. +91 84213 61224 The structural design of builcling(s) in this project has been done under his supervision. He has checked the soil report before laying pec for foundation in consultation with soil consultant. The formwork and concrete mix design have been done as per Is 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STAB1 LITY and SAFETY have been kept on record. 5. Preservation of Records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. i) __ ii) __ iii) _ '\ ours Faithfully, ~~ Signature "'ngmeer (Site Supervisor) Name: Mr. Darshan Jagdish Kankrej License No. (if any) 755 Phone No. +91 84213 61224 Place: Nashik