Bhushan Shintre 1, Gurusmruti', Near Utsav Garden, Nashik Road, Nashik 422101. Date: 31/03/2021. FORM-2A See MahaRERA order no. of2018] Engineer's Certificate For Quality Assurance. (Certificate No.05 (Five) for the quarter ending March 2021.) (Site supervisor's certificate) (To be uploaded quarterly) To, The "Chairman, Mahurgad Co. Op. Hsg. Soc Ltd.", GPA Holder M/s. Nice Home Partnership Firm Through Partner Mr. Nilesh Shinde & Other Two, Indumati Complex, Shop No.03, Nehru Nagar Bus Stop, Near Big Bazar, Nashik Road, Nashik 422101, Maharashtra. Subject: Certificate for quality of materials used and quality of Construction and workmanship for theWork of Re-Development of Commercial & Residential Building on the Sr.No. 11/1A/IA/1/2/3/1, Plot No.18, demarcated by its boundaries, (latitude and longitude of the end points) On or towards East Adj Colony Road, On or towards West Nala, On or towards South Plot No.19, On or towards North Colony Road & Open Space, 695.00 Sq Mtr. area of Nashik Division, Deolali Village, Nashik Taluka, Nashik District, admeasuring Soc Ltd., GPA Holder M/s. Nice Home being developed by Chairman, Mahurgad Co. Op. Hsg. Partnership Firm Through Partner Mr. Nilesh Shinde & Other Two. Reference: MahaRERA Registration Number P51600022034. Sir, of supervision of this real estate project. V We, have undertaken an assignment 1.OurResponsibility: and as per the approved plan and in accordance with the development permission To carry out the work in-situ or in the authorized of work and to carry out material testing submit certificate of supervision of work and laboratory and to ensure quality 1. Material Testing:- construction. checks on the basic materials, used in the we, have applied following mandatory i.Cement :- strength etc. as per IS code 3535:1986 soundness, setting time, compressive It has been tested for its fineness, or as per industry standards and its results are within the permissible or as per other relevant IS/85/NBC code, limits. ii. Coarse aggregate- It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 243011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. ii. Bricks/ blocks:- They have been tested tor water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/Ready-mix Concrete: - It has been tested for compressive strength for various periods as per IS 456:2000 and IS 1199 or as per other relevant IS/BS NBC codes, as per industry standards and its results are within permissible limits. v. Steelfor concrete: - It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials:- Other materials like sand. crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the Industry for a particular material. 2. W o r k m a n s h i p : - our supervision. We further certify that we hereby certify that work has been carried out under mark and the work has been acceptable within the workmanship and quality is satisfactory and up to the pemissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship:- installations have been carried Works of all the electrical wiring/connections/lift installation/other electrical out under authorized registered electrical engineer and its records has been maintained. The materials used conform to the relevant I.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer:- M/S. Reliable Consultants (Prop Er. Sanjeev Patel). The Promoters has engaged structural engineer has been done under his supervision. He has checked the soil structural design of buildings in this project and with soil consultant. The formwork c o n c r e te mix PCC for foundation in consultation report becfore laying relevant codes a s applicable. His periodic checks IS 10262:2009 or as per other design has been done as per SAFETY have been kept o n record. STABILITY and and certificates for of records: - 5. Preservation in the prescribed formats and will be Record of all test results of this project have been properly kept or for the period as required by any other provision of law least to the defect liability period preserved at up to the standard materials or any other item of works which were not conforming 6. Please specify not rejected. specifications and which were Yours Faithfully, Signature of Engineer Bhushan Shintre. Name Place Nashik