FORM-2A [MahaRERA order no. of 2018] ENGINEER'S GERTIFICATE FOR QUALITY ASSURANCE (Site superyisor's certificate) (To be uploaded quarterly) To, M/S Shweta lnfrastructure & Housing (l)pvt.Ltd. Samraat HQ/A33, Nice area ,street No.-7, Satpur MIDC , Nashik Maharastra -422 002 Qualitv Assurahce Certificate (certificate no. GDM/QA/OS for the quarter ending 21.o3.zozol Subject Certificate for quality of materials used and quality "of Construction and Workmanship for the Work of Samraat Gokuldham Project 02,Building C- Wing D of theProject situatedon survey No.206/1/3, Nashik Shiwar, demarcatedbyitsboundaries(latitude and longitude of the end points) s.No.206/111+2961112 (20.020382, 73.816811) to the North,S.No206/2 part,(2O.019917, 73.816768) to the South,ProposedS No205/1/P (20.020050, 73.816961)to the East,Samraat Gokuldham Project 01 & 18M Road(20.020076, 73.816645)to the West,Tal. & Dist.Nashik,PlN422003 admeasuring 2890 Sq. Mt.area being developed by M/S Shweta lnfrastructure & Housing (l) Pvt Ltd. Reference: MahaREM Registration Number- pS1600020375 Sir, I Er. Amit Pawar have undertaken an assignment of Supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testinq:- I have applied following mandatory checks on the basic materials, used in the construction. i. cement-lt has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lSl8s/NBC code, or as per industry standards and its results are within the permissible limits. ii. Goarse aggregate - impact value as It has been tested, for deleterious materials, clay lumps, crushing value, p"irs z43o119g6'oias per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits' iii. Bricks/ blocks - per lS 5454:1978 They have been tested for water absorption, crushing strength etc. as are or* per other relevant ls/8s/NBC code or as per industry standards and its results within permissible limits. iv. Goncrete/Ready-m ix Goncrete- It has been tested for compressive strength for various periods as per 15 456:2000 and its ls 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and results are within permissible limits' v. Steel for concrete- code or as It has been tested as per ls 2062:2011 or as per other relevant IS/BS/NBC per indUstry standardi for tensile strength, eiongation and gauge length etc' and its iesults are within permissible limits. vi. Testing of Other materials pipes and other materials like sand, crushed sand, floor tiles, fixtures and ffittings, to relevant project conform sanitary fittings tii.i out all items) . used .in this IS/BS/NBC code or "i". p"t standards laid down by the industry for a particular material' ", 2. WorkmanshiP:' we further certify I hereby certify that work has been carried out under our supervision. and the work has been that workmanship and quality is satisfactory and up to the mark per relevant code of practice' acceptable witrin tre permissiule limits of deviations as 3. Electrical Materials and workmanship: -. electrical installations Works of all the electrical wiring/connections/lift installation/other and its records have been carried out under authorized/registered electrical engineer B.S/ National I.s/ has been maintained. The materials used-conform to the relevant Building codes or as per industry standards' 4. Structural engineer: - promoters has engaged structural engineer'Mr.Jayantlnamdarhaving Licenses no. 165 having office no020 29702407.- cell no 9822035587 supervision. The structural design of buildings in this project has been done under his with soil He has checked thE soil report Sefore laying i,Cc tor foundation in consultation per ls 10262:2009 consultant. The formwork and concrete mix Oesign has been done as for or as per other relevant codes as applicable. His periodic checks and certificates STABILITY and SAFEry have been kept onrecord' 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed period or for the period as formats and will be preserved at least up to the defect liability required by any other provision of law to the 6. please specify materials or any other item of work which were not conforming standard specifications and which were not receded- Yours FaithfullY, Signature of Engineer (Site Supervisor) Name:Amit Pawar License no.(if any) Phone no. 9552673800 Place:Nashik -ffi:'5a-\