Mr. IVlandar lI. Salvi B.E.Ciwil Flat No. B 25, Suyojit tawns Phase-u, I Rathi Amari, Ned Mahatma Nagd, Nashik-422007. Mob. No. 8275O2377a Email - msdtrsalviT t@gmail. com FORM-2A ISee Maha RERA order no. of 2018] ENGINEER'S CERTIFICATE FOR QUALITY ASSUR,ANCE (site supervisor's certif icate) To, The Directors Sun Infrastructure P!t, Ltd., F-1l2, Suyojit Heights, Opp. Rajiv Gandhi Bhavan, Sharanpur Road, Nashik Quality Assurance Certif:cate (Certificate no P51600019106 for the quarter ending June.2019) Subject Certificale for quality of materials used and quality of Construction and workmanshjp forthe Work of "Suyoiit Viridian Vallis Phase-II, E-5, VMDE" No. of Building(sl 1 of the Project situated on the Plot bearing Out of Survey No, S,No,145/1, S,No.145/3, S.No.149l1, S.No.l49/2, S.No.151, S.No.152, S.No.155/2, (latitude and Iorgitude of the end poirts) 12 MTRS ROAD to the North, BUILDINC E8 AND PROPOSED BUILDING E7 to the South, PROPOSED BUILDINC E6 to the East, BUILDING E4 to the West ofDivision Nashik Situated at Village Makamalabad, Taluka & Dist ct Nashik, within the jurisdiction of Sub Re8istrar Nashik, and within limits of Nashik Municipal Corporation, Nashih PIN 422007 admeasuriog 2B67.04sq.mts. area being developed by [Sun lnfrastructures P\,t. Ltdl Reference: MahaRERA Registration Number- P51 60001 91 06 Sir. I Mr, Mandar Salvi have undertaken an assignment of supervision ofthis real estate project. '1. Ou. Responsibility: - To carry oui the work in accodance with the development permission and as per the approved plan and submit certilicate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testirq:- llwe, have applied following mandatory checks on the basjc materials, used in the construction. i. Cement- Stlength etc, aS per lt has been tested for its fineness, Soundness, Setting time. compressive isss,rggo or as per othe. relevant ts/85/NBC code. or as per industry standards is and"oo" its results are within the permissib:e limits' ii. coarse aggregate - lthaSbeentested,fordeleteriousmaterials,claylumpS,crushingvalue,.impactvalueas o.tlS z+SOileao - as per other relevant IS/BS/NBC code or as pe' industry standards and rts results are wlthrn the permlssrble limits' ii i. Sricks/ blocks - Thevhavebeentestedforwatelabsorption,crushingstrengrhetc,aSperlS5454:1978or ;J;L; ;il;;;;;;;i rirasrNec code or as per induitry srandards a4d its results are within permissible limits. iv. ConcretelReady-mix Concrete- periods as per 15.456:2000 and lS It has been tested for compressive strength ior various i199 ;;p;;;G"t relevant lS/BSINBCcodes' as per industry standards and its results are within Permissible limits. v. Steel tor concrete- code or as per It has been tested as per lS 2062:2011 or as per other relevant IS/BS/NBC tor tensale strength, elongaiion and gauge length etc and its results are inJustw "t"norro" limits. within permissible vi, Testing of Other materials Sanitary other materials like sand, crushed Sand, floor tiles, flXtures and fltting.S,,ipes and or as riiinot [i"t ort ,ll items) used in lhis project conform lo relevant lS/BS/NBC code "i". la;d down by the industry for a particular material' per s-tandards 2. mans hip: - We further cerlify l/ we hereby certify that work has been carried out under our supervis'on' work has been il;*;;k*;;;iirnJ qualitv is satisfactory and up to the per mark and.the relevanl code of practice *itt ii tt e peimissible timits of deviatrons as "i""puof" 3. Electrical Materials a.d workmatshiP: - installations have Works of all the electrical wirlng/connections/lift installation/other electrical under author-ized/reglstered electrical engineer and its.records has been 1""" ""rri"O ""i ;"terials used confoim to the relevant l's/ B S/ National Building codes or ;;;;;;;.H; as per industry standards. 4. Stauctural engineer: - Promoters has engaged structural engineer M/s. Shanghvi-& Associates Consultants Pvt Ltd having Licenses no having office no 02226144a32' The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultalion with soil consultant The formwork and concrete mix design has been done as per ls 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificaies ior STABILITY and SAFEfi have been kepl on record 5. Preservafion of rccords: - Record of all test resulls of this project have been properly kept in the prescribed formats and will be preserved at least up to the detect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which wete not conforming to the standard specifications and which were not rejected. Yours Faithfully, \w Signalure of Engineer (Site Supervisor) M.. Mandar Salvi Phone no.8275023778 Place: Nashik