Mr. Rajexr PatiX B.E.Ciwil Flat No. B-25, Suyojit Phase-ll, K Rathi Arnari, Near Nagar, Nashik-422007. Mob. No. 9819667298 Email - rajendra.pa FORM.2A I See Maha RERA order no. of 2018] ENGINEER'S CERTIFICATE FOR QUALTTY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, The Directors Sun Infrastructure Pvt. Ltd., F -L / 2, Suyojit Heights, Opp. Rajiv Gandhi Bhavan, Sharanpur Road, Nashik Qual itv Assu rance Certificate (Certificate No P51600019048 for the quarter ending September- ,tl rl $ubject: Certificate for quality of materials used and quality of Construction and nship for the work of "suyojit viridian vallis Phase-II, E-3, VIVIDE" No. of Building[s] l" e Froject situated on the Plot bearing out of survey No. s.No.145/1, s.No.1as/3 s .N L49 /L, S.No.149/2, S.No.151, S.No.152, S.No.155/2, (latitude and longirude of the p nts l I 2 MTRS ROAD to the North, BUILDING EB to the South, PROPOSED BUILDING E4 to the BUILD N (; E2 to the West of Division Nashik Situated at Village Makamalabad, Taluka & Disrrim N within the jurisdiction of Sub Registrar Nashik, and within limits of Nashik Municipal Corpora N AS hik, PI N 422007 admeasuring286T.04sq.mts. area being developed by [Sun Infrastructures Pvt. l Reference: MahaRERA Registration Number- P51600019048 Sir, I Mr. Rajendra Patil have undertaken an assignment of supervisicn of th real estate project. 1. Our Responsibility: - : .l To carry out the work in accordance with the development permission a per the approved plan and submit certificate of supervision of work and to carry out m I tegting in-situ or in the authorized laboratory and to ensure quality of work and l ,' 1. Material Testing:- l/we, have applied fol lowing mandatory checks on the basic materials, uscrl i construction. i. Cement- It has been tested for its fineness, soundness, settin g time, compressive (ID per lS code 3535:1986 or as per other relevant IS/BS/N BC code, or as per ind standerds and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, im ea$ per lS 243011986 or as per other relevant IS/BS/NBC code or as per" ind ustry nda,rds and its results are within the permissible limits iii. Bricks/ blocks * They have been tested for water absorption, crushing strength etc" as per l\) 197'8 or as per other relevant IS/8S/NBC code or as per industry standards and its :ffIe' within permissible limits. iv. Concrete/Ready-m ix Concrete- It has been tested for compressive strength for various periods as per 1S 45rt) and l$ 1 199 or as per other relevant |S/BS/NBC codes, as per industry standards a results are within permissible limits. v. Steel for concrete- It has been tested as per lS 2062:2011 or as per other relevant IS/BSiNIBC e 0r as per industry standards for tensile strength, elongation and gauge length etc. and It* are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and {fittings, p d sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/N code or as per standards laid down by the industry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We er certify that workmanship and quality is satisfactory and up to the mark and the has been acceptable within the permissible limits of deviations as per relevant code of 3. Electrical Materials and workmanship: - Works of allthe electricalwiring/connections/lift installation/other electrical in ,ion$ have been carried out under authorized/registered electrical engineer and its has been maintained. The materials used conform to the relevant l.S/ B.S/ National Buil g codes or as per industry standards. ;l I 4. $tructural engineer: - Promoters has engaged structural engineer Mls, Shanghvi Pvt Ltd having Licenses no 1 The structural design of buildings in this project has been l-l r> has checked the soil report before laying pCC for with soil co NS u Ita nt. The fo rmwork and con crete m ix d est J n has a I 0CIs or AS per other re levant cod CS ct5 appli ca ble H is pe for STA B LITY a nd SAFETY have 0n record 5. Preservation of records Reco rd of all test resu l+^ lt5 of th is proJ ect h ave bee lt properly kept the nr formats and will be preserved at least up to the defect liability pe riod or for the peri od by any other provision of law 6. Please specify materials or any other item of work which we ot rng the standard specifications and which were not rejected. r- rA ithfully Signature of Englneer Mr +it Phone 196572$8 Flashik xlO volv )onu i