,N*,ffiffiffiffi s0iftru.ddusdtrs&6aqd ENGINEER',S CERTTFTCATE FOR qUALrry ASSURANC=Ei" DII.: , To, Shri Naryan Labhu Sarode Plot No.9, Pandurang Niwas, Sinhastha Nagar, Bhadrapad Sector, CIDCO, Nashik - 422009 Qualitv Assurance Certificate (Certificate No. 1 for the quarter ending 31't March ,2OL9l Subject: Certificate for quality of materials used and quality of Construction and workmanship for the Work of Sarode Sankul situated on the Plot No. 37 to 40 bearing Survey No. 55/UB demarcated by its boundaries Adj. Gat No. 55/1 Part to the North, Plot No. 36 to the South, 12 Meter Wide Road to the East, Plot No. 41 lo 47 to the West of Division Nashik, Village Chunchale, Taluka Nashik, District Nashik, PIN - 422010 admeasuring 843 Sq. Mtrs. Area being developed by Shri Narayan Labhu Sarode. Reference: MahaRERA Registration Number - P51600018930. Sir, We, Sarode Builders and Land Developers have undertaken an assignment of supervision of this real estate project. Our Responsibility: To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out materialtesting in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. 1. MaterialTesting: We have applied following mandatory checks on the basic materials, used in the construction. i. Cement_: It has been tested for its iineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lS/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse Aggregate: It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per ls 243011986 or as per other relevant ls/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks / Blocks: They have been tested for water absorption, crushing strength etc. as per lS 5454:1'978 or as per other relevant lS/85/NBc code or as per industry standards and its results are within permissible limits. iv. Concrete / Ready-Mix Concrete: It has been tested for compressive strength for various periods as per j.5 456:2000 and lS 1199 or as per other relevant ls/Bs/NBC codes, as per industry standards and its results are within permissible limits. v. Stee! For Concrete: It has been tested as per ls 2062:2011 or as per other relevant ls/Bs/NBc code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing Of Other Materials: other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant |S/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship: We hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials And Workmanship: Works of all the electrical wiring/connections/lift installation/other electriibl installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structural Ensineer: Promoters have engaged structural engineer Mr. Shirish Ner having License No. 162 having office at B14, Sharmila Society, Old Gangapur Naka, Gangapur Road, Nashik and Cell No. 9422250371. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant' The formwork and concrete mix design has been done as per lS 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETy have been kept on record. 5. Preservation Of Records: Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. There were no materials or any other item of works which were not conforming to the standard specifications and which were not rejected. Yours Faithfully, Signature of Engineer (Site Supervisor) Name: Dhanesh Narayan Sarode License No.: Not Applicable Phone No.: +91 942225L497 PIace: Nashik