FORM-2A [See MahaRERAorder no. of 2018] ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) To, (Period Ending 31/03/2022) MIS ADITYA BUILDCON (Partnership Firms), Flat No.2, 2nd Floor, Saisrushti Apt, B/H Palm Hotel, Pathardi Road, Near Eco NASHIK-422010 City, Quality Assurance Certificate (Certificate no for the quarter ending 31/03/2022) Subject: Certificate for quality of materials used and quality of workmanship for the Work of No. of Building(s)Wings(s) of the ADITYA Construction and Phase of the project situated on the Plot No.7, Survey No AVENUE Shiwar, Nashik 422010. demarcated by its boundaries 319/2A/2B/1, of Pathardi end points) Plot No 8 to the North. 7, Plot no 6to the (latitude and longitude of the East, 18 mt DP Xoad to the West of Division Nashik South, Plot No 24 and 25 to the Viliage Nashik Taiuka Nashik District PIN 422009. Admeasuring 630.00 sq.mts. area being Borade of M/s. Aditya Buildcon developed by Mr. Mohan Reference: MahaRERARegistration Number- P51600017211. Sir, VWe Mohan Madhukar Borade have real estate project. undertaken an assignment of supervision of this 1. Our Responsibility: - Tocarry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Materia! Testing: - I/we, have applied following mandatory checks on the basic construction. materials, used in the i. Cement It has been tested for its fineness, soundness, setting time,compressive strength etc. as per IS code 3535:1986 or as per other relevant IS/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per oth¹r relevant and its results are within the IS/BS/NBCcode or as per industry standards permissible limits. iii. Bricks/ blocks - They have been tested for water or as per other relevant absorption, crushing strength etc. as per IS 5454:1978 within permissible limits.IS/85/NBC code or as per industry standards and its results are iv.Concrete/Xeady-mix Concrete Ithas been tested for IS 1199 or as per othercompressive strength for various periods as per 15 456:2000 and results are relevant IS/BS/NBCcodes, as per industry within permissible limits. standards and its V. Steei for concrete It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other mäterials Other materials like sand, crushed sand, floor tiles, fixtures and sanitary fittings etc. (List out all items) used in this project conform{fittings, pipes and IS/BS/NBC code or as per standards laid down by the industry for a to relevant 2. Workmanship: - particular material. /we hereby certify that certify that workmanshipwork has been carried out under our supervision. We has been acceptable within thequality is satisfactory and up to the mark and thefurther and work practice. permissible limits of deviations as per relevant code of 3. Electrical Materials and workmanship: - works of allthe electrical installations have wiring/connections/lift installationother electrical its records has beenbeen carried out under authorized/registered maintained. The materials National Buiiding codes or as per industry used contorm toelectrical engineer and the relevant 1.S/ B.S/ standards. 4. Structural engineer: - Promoters has having Licenses no.engaged structural engincer Mr. Mohan Madhukar Borade having office no.- cell no Ihe structural design of He has checked the soil buildings itn this proicct has bccn done report Soil consultant. The formwork before laving PCC for foundationunder his supervisiofi. in consultation and concrete mix design have been with 10262:2009 as per other relevant codes as applicable. His or done as per Is certificates STABILITY and SAFETY have been kept on for periodic checks and 5. record. Preservation of records: Record of all test results of this project formats and will be preserved at least up tohave been properly kept in the prescribed the defect liability period or for the as required by any other provision of law period 6. Please specify materials or any other item of work standard specifications and which were not rejected. which were not conforming to the Nil Yours FaithfuBy, MOHAN AADIRAR BORADE Signature of Ehgineer (Site Supervisor) Name:- Mohan Madhukar Borade. Place: Nashik