Off. : 6, Ashtavinayak Residency, Sadguru Nagar. Mumbai- Agra Highway, Nashrk - 422009 RAHUL B. THAKARE Email.: thakare_rahuI2006@rediffmail com Mobile No. : 098810760531 Tel.: 0253- 2472484 ENGINEERS & GOVT. CONTRACTORS FORM-2A [see Maha-RERAorder NO.5 of 2018] ENGINEER'S CER'I1F1CATE FOR QUATITI ASSURANCE (site supervisor's certificate - To be uploaded quarterly) To, Date: - 12 ,July 2019 The Mr. Rahul Bhaskarrao Thakare & Late Ajay Abaji Chavan Legal Heir Mrs, Manisha Ajay Chavan & Other Swami Vivekanand Nagar, Nr. Water Tank, Opp. Irrigation Colony, Makhmalabad, Panchvati, Nashik 422003 Quality Assurance Certificate (Certificate No. SA/03/19 for the quarter ending Apr-19 to July-ro) Subject : Certificate for quality of materials used and quality of Construction and workmanship for the Work of Shree Raj Vihar No. of Building One of the phase of the Project situated on the Plot bearing Survey No. 417/'JA Final Plot No. 104 demarcated by its boundaries 12 Mtr. Colony Road to the North Plot No. 105 to the South Open Space to the East Plot No. 103 to the West of Division Nashik Village Nasik Taluka Nasik District Nashik PIN 422003 admeasuring 320 sq.mts. area being developed by Mr. Rahul Bhaskarrao Thakare & Late Ajay Abaji Chavan Legal Heir Mrs, Manisha Ajay Chavan & Other. Reference: MahaRERA Regi~tration No. P516oo017066 Sir, I I We Jayesh Batavia have undertaken an assignment of supervision of this real estate project Our Responsibility: To (;8r1'Y out the work in accordance with the development approved permission and as plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. 1.. MateliaI Testing: [ I We, have applied following mandatory checks on the basic materials, used in the construction. i) Cement- Ithas been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 01' as per other relevant IS/8s/NBC code, or per industry standards and its results are 'Within the permissible limits. ii) Coarse Aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. hva G.uDay .... iii) Bricks/ Blocks - They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/8S/NBC code or as per industry standards and its results are within permissible limits. iv) Concrete / Ready-mix Concrete - Ithas been tested for compressive strength for various periods as 456:2000 and IS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v) Steel for Concrete - It has been tested as code or as per IS 2062:2011 or as per other relevant IS/Bs/NBC per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi) Testing of Other Materials - Other materials like sand, crushed sand, floor tiles, fixtures and fillings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. 'Vorkmanship: - I I we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and Workmanship: - Works of all the electrical wiring/ connections / lift installation electrical installations have been carried out under authorized /registcred electrical engineer and it'>records has been maintained. The materials used conform to the relevant 1.S/ B.S/ National Building codes or as per industry standards. 4. Structural Enginecr: - Promoters has engaged structural engineer Mr. Jayesh Batavia having Licenses No. Al\1087173-5 having Cell No. +91253 2574016 The structural design ofbuilding(s) in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The forrnwork and concrete mix design has been done as per Is 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABIUTY and SAFETY have been kept on record. 5. Preservation of Records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. i) --NA-- __ ti) _ iii) _ Yours Faithfully, Signature of Engineer (Site Supervisor) Name: RAH UL B. THAKARE License No. (if any) NMC-248 Phone No. +91988 1076053 Place: Nashik hva G.uDay....