FORM-2A [see Maha-RERA order NO.5 of 2018] ENGINEER'S CERTIFICATE FOR QUATITY ASSURANCE (site supervisor's certificate - To be uploaded quarlerly) To, Date: - 31stMarch 2019 The Shaikh Parveen Gamir and Other, F-05, Saniya House, Ajmeri Colony, Khode Nagar, VVadalaRoad, Nashik 422006. Quality Assurance Certificate (Certificate No. SAj03/19 for the quarter ending Nov-17 to March-io Subject: Certificate for quality of materials used and quality of Construction and workmanship for the Work of Kaabil Apartment No. of Building One of the phase of the Project situated on the Plot bearing Survey No. 5/2 Final Plot No. 75+76 demarcated by its boundaries Plot No. 29 to the North 12 Mtr. Road to the South Plot No.1 & Part of Plot No. 2 to the East Plot No. 32 to the West of Division Nashik Village Nasik (M Corp.) Taluka Nasik District Nashik PIN 422012 admeasuring 560 sq.mts. Area being developed by Gopal Developers. Reference: MahaRERARegistration No. P51600018624Sir, 1/ We Er. Harshad k Bhamare has undertaken an assignment of supervision of this real estate project. Our Responsibility: To carry out the work in accordance with the development approved permission and as plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBCand or other relevant code of practice. r.Material Testing: I / We, have applied following mandatory checks on the basic materials, used in the construction. i) Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant IS/8S/NBCcode, or per industry standards and its results are within the permissible limits. ii] CoarseAggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/NBCcode or as per industry standards and its results are within the permissible limits. iii) Bricks/ Blocks - They have been tested for water absorption, crushing strength etc. as per IS5454:1978 or as per other relevant IS/8S/NBC code or as per industry standards and its results are within permissible limits. iv) Concrete / Ready-mix Concrete - It has been tested for compressive strength for various periods as 456:2000 and IS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v) Steel for Concrete - It has been tested as code or as per IS 2062:2011 or as per other relevant Is/Bs/NBC per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi) Testing of Other Materials - Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship: - I / we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant codeof practice. 3. Electrical Materials and Workmanship: - Works of all the electrical wiring! connections / lift installation electrical installations have been carried out under authorized /registered electrical engineer and its records has been maintained. The materials used conform to the relevant 1.5/ 8.5/ National Building codes or as per industry standards. 4. Structural Engineer: - Promoters has engaged structural engineer M/s Deltacom Structural Consultant having LicensesNo. NMC41 having Cell No. +91 942 2252335 The structural design of building(s) in this project has been done under his supervision. He has checkedthe soil report before laying PCCfor foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per Is 10262:2009 or as per other relevant codes as applicable. His periodic checksand certificates for STABILITYand SAFETYhave been kept on record. 5. Architect-Promoters have engaged Architect -Ar.Saurabh Amrutkar asa Project Architect LicenseNo. - __ having Cell no.9766444333.The construction of the building is done under his supervision as per sanctioned drawings. He has done periodic inspection of the work as per working drawings prepared by him & evaluation of construction work. 6. Preservation of Records:- Record of all test results of this project have been properly kept by the promoter in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 7. please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. i) --NA-- _ Yours Faithfully, l ~ Signature of Engineer (Site Supervisor) Name:- Er. Harshad K Bhamare LicenseNo. (if any) Q (y) I ~:tg_q£~ Phone No. 7588658058 office no. Place: Nashik