FORM -2A [see Maha-RERA urder NO.5 of 2018] ENGINEER'S CERTIFICATE FOR QUATITY ASSURANCE (site supervisor's certificate - To be uploaded quarterly) Tu, Date: - 31st March 2019 The Sai Construction, 202, Gemini Height I, Indira Nagar, Pathardi Road, Nashik 422010. Quality Assurance Certificate (Certificate No. GH/03/19 for the quarter ending Aug-17 LoMarch-io) Subject: Certificate for quality of materials used and quality of Construction and workmanship for the Work of Gemini Heights IINo. uf Building One of the phase of the Project situated on the Plot bearing Survey No. 295/4 Final Plot No. 24+25 demarcated by its boundaries Plot No. 23 to the North Plot No. 26 to the South Sr. Nu. 315 to the East 9 Mtr Colony Road to the West of Division Nashik Village Nasik (M Corp.) Taluka Nasik District Nashik PIN 422010 admeasuring 500 sq.rnts, area being developed by Sai Construction. Reference: MahaRERA Registration No. PS1600010s13 Sir, I/ We Manish Mishra have undertaken an assignment of supervision of this real estate project. Out' Responsibility: To carry out the work in accordance with the development approved permission and as plan and submit certificate of supervision of work and to carry uut material testing in-situ or in the authorized laboratury and tu ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. 1. Material Testing: 1 / We, have applied following mandatory checks on the basic materials, used in the construction. i) Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant IS/Bs/NBC code, or per industry standards and its results are within the permissible limits. ii) Coarse Aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 2430:1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. hva G.uDay .... Bricks/ Blocks - iii) They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/8S/NBC code or as per industry standards and its results arc within permissible limits. iv) Concrete / Ready-mix Concrete - It has been tested for compressive strength for various periods as 456:2000 and IS 1199 or as per other relevant IS/KS/NBC codes, as per industry standards and its results are within permissible limits. v) Steel Ior Concrete - It has been tested as code or as per IS 2062:2011 or as per other relevant ls/Bs/N HCper industry standards for tensile strength, elongation and gauge length etc. and its results are 'within permissible limits. vi) Testing of Other Materials - Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (LL<;t out all items) used in this project conform to relevanl IS/nS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship: - I I we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and Workmanship: - Works of all the electrical wiring/ connections / lift installation electrical installations have been carried out under authorized /registered electrical engineer and its records has been maintained. The materials used conform to the relevant 1.S/ B.S/ National Building codes or as per industry standards. 4. Structural Engineer: - Promoters has engaged structural engineer Mis Dcltacom Structural Consultant having Licenses No. NMC41 having Cell No. +91942 225 2335 The structural design ofbuilding(s) in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per L.,10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABIliTY and SAFETY have been kept on record. 5. Preservation of Records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. i) __ _--NA-- __ ii)_ iii) _ ~ithfUnY, Signa~ (Site Supervisor) Name: Manish Mishra License No. (if any) __ Phone No. 8788487018 Place: Nashik hva G.uOay....