FORM.2A [See MahaRERA Order No. of 20181 EHGINEERIS CERTIFICATE FOR qUALITY ASSURANCE (Site Supervisor's Certificate) i {To be uploaded quarterly} To, The RAIASHREE CONSTRUCI-ION , KK. Wagh Agriculture Collage, Near Rasbihari International School Road, Mumbai-Agra Highway, Adgaon, Nashik QualiW Assurance Certifi cate (Certificate no 9 for the quarter ending 31$ March 2021 Certificate) Subiect : Certificate for quality of materials used and quality of Construction and workmanship for the Work of 2 No. of Building(s)/- Wings(s) of the- Phase of the project situated on the plot bearing C. S. No./C.T.S. No./ Survey No./Final plot no.233 demarcated by its boundaries {latitude and Iongitude of the end points)S, No. 235 & Open Space to the North Plot no. 10,11,15 & Colony Road Out of S. No. 233t2 to the South Part of 5. NO. 233/2lB/1to the East S. No. 233/1to the West of Division Nashik village Nashik Taluka Nashik District Nashik PIN 422003 admeasuring 6000.00 sq.mtrs. area being developed by [Promote/s Name RA,ASHREE CONSTRUCTION] Reference: Ma ha RERA Registration N u m be r- P5 160000 10467 Sir, l/ lAte Pankaj Pawar have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. MaterialTesting:- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant |S/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per ls 243011986 or as per other relevant |s/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as perls 5454:1978 or as per other relevant |S/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/Ready-Mix Concrete- It has been tested for compresslve strength for various periods as per 15 456:2000 and ls ].1gg or as per other relevant ls/Bs/NBc codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per lS 2062:2oLL or as per other relevant ls/Bs/NBc code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc' {List out all items) used in this project conform to relevant ls/Bs/NBc code or as per standards laid down by the lndustry for a particular material. 2. Workmanship:- l/ we hereby certifY that work has been carried out under our supervision. we further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.s/ B.S/ National Building codes or as per industry standards. 4" Structural engineer: - Promoters has engaged structural engineer Mr. Prasnna Bhore having Licenses no. 41 having office no 3.- cell no 0253-2313180/ 9422246969. --! The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has beendone as per ls 10252:2OOg or as per other relevant codes as applicable. His periodic checks and certificates for STABILIry and SAFETy have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which was not conforming to the standard specifications and which was not rejected. Signature of Engineer {Site Supervisor} Name: Pankaj Pawar License no.{if any} Phone no.9028178080 Place: Nashik ! *__ FORM.2A [See MahaRERA Order No. of 20181 ENGINESFI'S CERTI FICATE FOR QUATITV ASSURAN CE (Site Superuiso/s Certificate) (To be uploaded quarterly) ', To, The RAIASHREE CONSTRUCIION , KK. Wagh Agriculture Collage, Near Rasbihari International School Road, Mumbai-Agra Highway, Adgaon, Nashik Qualiw Assurance Certificate (Certificate no 10 for the quarter ending 30th June 2021 Certificate) Subiect : Certificate for quality of materials used and quality of Construction and workmanship for the Work of 2 No. of Building(s)/- Wings{s} of the- Phase of the project situated on the plot bearing C. S. No./C.T.S. No./ Survey No./Finalplot no.233 demarcated by its boundaries {latitude and longitude of the end pointslS, No. 235 & Open Space to the North Plot no. 10,11,15 & Colony Road Out of S. No. 23312 to the South Pan of S. NO. 233l2lB/L to the East S. No. 23311 to the West of Division Nashik viltage Nashik Taluka Nashik District Nashik PIN 422003 admeasuring 6000.00 sq.mtrs. area being developed by [Promoter's Name RAIASHREE CONSTRUCTION] Reference: Ma ha RE RA Registration N u m ber- P5 150000 10467 Sir, U llrle Pankaj Pawar have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. MaterialTestine:- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lSl85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterioi:s materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as perls 5454:197g or as per other relevant lS/85/NBC code or as per industry standards and its results are within permissible limits. iv. ConcretelReady-Mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per 15 2062:201L or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc- (List out all items) used in this project conform to relevant |S/BS/NBC code or as per standards laid down by the lndustry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - Works of all the electrical wiringfconnections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer Mr. Prasnna Bhore having Licenses no. 41 having office no 3.- cell no 0253-2313180/ 9422246869. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per ls 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILIry and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the presribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 5. Please specify materials or any other item of work which was not conforming to the standard specifications and which was not rejected. Yours Faithfully, Signature of Engineer {Site Supervisor} Name: Pankaj Pawar License no.{if any} Phone no.9028178080 Place: Nashik