-t umesh bogul orchitect first floor, podmo-vishwo cenler, old pondil colony. noshik. tel.- 0253 2579667. e.moil - orumeshbl0@gmoil.com ARCH ITEET'S CE RTI FI CATE Date: 30/03 |2OZA. To The "M/s Rajashree Construction Partnership firrn", 307, Padma-Vishwa Center, Old Pandit Colony, Nashik. Subject: Certificate of Percentage of Completion of Construction Work of "OYESTER C, D, E WlNG", the Project situated on the S.NO.23.!l2lBlL" Demarcated by its boundaries (latitude and longitude of the end points - 20"01'38.67"N, 73"49'42.83"81 On or towards East ADJ. S. N0. 233 12/ sl 3.lP) On or towards West ADi. s.NO. 233/ue/u4 0n or towards South 7.50 m. wide road & F.no.10,11,15 On or towards North ADJ. OPEN SPACT of Division Nashik, Taluka- NASHIK, Dist- NASHIK-422AA3 admeasuring 6000.00 5Q.M. Area being developed by "M/s Raiashree Construction Partnership firn'1." Sir, tAr. UMESH BAGUL have undertaken assignment as Architect certifying Percentage of Completion of Construction Work of the "OYESTER C,D, E WING" the Project , situated on the S.NO. 233/2 l1lL. Ot Division Nashik, Tal- NASHIK, Dist- NASHIK-422003 admeasuring 6000.00 5Q.M. area, being developed by "M/s Rajashree Construction Partnership firm." 1. Following technical professionals are appointed by owner / Promoter :- i. Mr. Umesh Bagulas Architect ii. Mr. Frasanna Bhore as Structural Consultant iii. Mr. Pankaj Pawar as Site Supervisol' Based on Site lnspection, with respect to each of Wing of the aforesaid Real [state Project, I certify that as on the date of this certificate, the Percentage of work done for each of Wing of the Real Estate Project is as per table A herein below. The percentage of the work executed with respect to each of the activity of the entire phase is detailed in Table B. Ar. dp Urfi[ B.$il cAa3/159et Page 1 of 3 umesh bogul orchilect first floor, podmo-vishwo center. old pondil colony, noshik. tel.- 0253 2579667. e.moil - orumeshblO@gmoil.com Table A "OYESTER C, D, E WING' 5r. No Tasks I Activity Percentage of work done {%} WING C WING D WING E 1 Excavation 100 100 100 1 L Plinth 100 100 0 ? number of Podiums N.A. N.A- N.A. 4 Stilt Floor 100 100 0 5 Slabs of super Structure 100 100 0 6 lnternal walls, lnternal Plaster, Floorings within Flats I 75 100 0 Premises, Doors Windows to each of the Flat I Premises 7 Sanitary Fitting within the Flat,/ Premises, Electrical 30 100 0 Fittings within the Flat I Premises I Staircase , Lifts Well and Lobbies at each Floor level 50 L00 n connecting Staircase and Lifts, Overhead and Underground Water Tanks 9 The External plumbing and external plaster, elevation , 20 100 0 completion of terraces with waterproofing of the Buildine/ Wins, 10 lnstallation of lifts, water pumps, Fire Fighting Fitting and 0 0 0 Equipment as per CEO NOC, Electrical Fitting to Common Areas, electro, mechanical equipment Compliance to conditions of environment / CRZ NOC, Finishing to entrance lobby / s, Plinth protection , paving to areas appurtenant to BuildinglWing, Compound Wall and all other requirements as rnay be required ts obtain Occupation / Completion Certificate Ar. [f=*t] F]agug cA;: " 5*S7 Page 2 cf 3 umesh bogul orchileci firsl floor, podmo-vishwo center, old pondit colony, noshik. tel.- 0253 2579667. e.moil - orumeshblO@gmoil.com TABLE. B lnternal & External Development works in respect of the entire "OYESTER €, D, E WIN"G" S. no. Common areas and Proposed { Yes/ Percentage of Details Facilities, Amenities No) work done 1,. lnternal Roads & Footpaths No 0 Not Applicable 2. Water supply YE5 0 To be obtained from NMC on completion of the project 3. Sewerage { chamber, lines, YE5 50 Work in progress septic tank, STP) 4. Storm Water Drains No 0 NA 5. Landscaping & Tree yes 0 As per NMC Planting reguirement. 6. Street Lighting lVo n NA 7. Community Buildings No 0 NA a Treatment and disposal of yes 0 As per NMC sewage and sullage water requirement 9. Solid Waste rnanagement yes 0 As per NMC & Disposal requirement 10. Water conservatioil, rain Yes 0 Work yet to start Water harvesting lL. Energy management No 0 NA 12. Fire protection and fire No n NA safety requirements 13. Electrical meter room, sub- Yes 0 Construction of station, receiving station meter room yet to start L4. Open Parking Yes 0 Work yet to start Yours Faithfully Signature & name AR. UMESH BAGUL {License No. CA193115997} ; ' lr. Umcsh Brgul cA/93/15997 Page 3 of 3