GANESH V. SHIRSAT BL (Civil) Regd.Office: Alp - Bhandurl,Tal- Chandwad, Nashik, Contact: 7743905071 Email- shirsatgl@gmail.rom FORM - 2A [ see MahaRERA order No.5 of 2016] ENGINEER'S CERTIFICATE FOR QUATITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, The Director, Shreya Properties Pvt. ltd Off. 2 Jeevansathi Apartment, Bhabha Nagar. Nashik. Quality Assurance Certificate (Certificate No. ShreyalJan12019for the quarter ending Jan 2019) Subject. Certificate for quality of materials used and quality of Construction and workmanship for the Work of Shreya Heights No. of Building 01 of the Project situated on the plot bearing Sr. No. 792/1A11+2+3, Final Plot No. 7+6 demarcated by its boundaries Sr. No. 792 to the North Piol No.8 to the East D.P. Road to the West Plot No 5 & 6 to the South to the west of Division Nashik Village Nashik Taluka Nashik District Nashik PIN 422002 admeasuring 854 Sq. MtL Area being developed by Shreya Properties Pvt. Ltd. Reference: MahaRERA Registration No. - P51600006371 II We Ganesh V. Shirsat have undertaken an assignment of supervision of this real estate project. Our Responsibility: To carry out the work in accordance with the development approved permission and as plan and submit certificate of supervision of work and to carry out material testing In-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. 1. Material Testing: I I We, have applied following mandatory checks on the basic materials, used in the construction I) Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535'1986 or as per other relevant IS/85/NBC code, or per Industry standards and its results are within the permissible limits. ii) Coarse Aggregate - II has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430: 1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits iii) BricksJBlocks - They have been tested for water absorption, crushing strength etc. as per IS 5454'1978 or as per other relevant IS/85/NBC code or as per industry standards and its results are within permissible limits. iv} Concrete / Ready-mix Concrete - It has been tested for compressive strength for various periods as 456:2000 and IS 1199 or as per other relevant IS/BSINBC codes, as per industry standards and its results are within permissible limits. GANESHV. SHIRSAT B.E.(Civil) Regd.Office: Alp - Bhanduri. Tal- Chandwad. Nashik. Contact: 7743905071 Email-shirsatgl@grnail.com v) Steel for Concrete - It has been tested as code or as per IS 2062:2011 or as per other relevant IslBslNBC per Industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits vi) Testing of Other Matenals - Other materials like sand. crushed sand, floor tiles, fixtures and fittings. pipes and sanitary fittings etc. (List out all items) used in this project confomnto relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship: - II we hereby certify that work has been carried out under our supervision We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and Workmanship: - Works of all the electrical wiringl connections I lift installation electrical installations have been carried out under authorized Iregistered electrical engineer and its records has been maintained. The materials used confomnto the relevant I.SI B.SI National Building codes or as per industry standards. 4. Structural Engineer: - Promoters has engaged structural engineer Mr. Ganesh V. Shirsat having licenses No. 259 having Cell No 7743905071 The structural deSignof building(s) in this project has been done under his supervision. He has checked the soil report before laying PCC for foundahon in consultation with soil consultant. The fomnworkand concrete mix design has been done as per Is 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of Records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the penod as required by any other provision of law. 6. Please specify materials or any other item of work which were not conforming to the standard specifications and Whichwere not rejected. i) NA, _ ii) _ iii) _ Yours Faithfully. ~ (,"'~t:""'VIJ,., ~lr)'1 Signature of En~neer (Site Supervisor) Name' Ganesh V. Shirsat License No. (If any) 259 Phone No. 7743905071 Place: Nashik