FORM-2A lsee trllahaRERA order no. of 20181 ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (Site su Pervisor's certifi cate) (To be uploaded quarterly) To, The MIS Gokul Infrastructure, M/S Pooja Kutir Nirman Pvt. Ltd., M/S Rajendra M. Developers & Builders Pvt. Ltd., Qualitv Assu rance Certif icate (Certificate no.SA/0l/QA for the quarter ending) Subject : Certificate for quality of materials used and quality of Construction and workmanship for the Work of GOKUL ONE No. of Building(s)/ 01 Wings(s) of the _ Phase of the project situated on the plot bearing C. S. No./C.T.S. No./ Survey No./Finalplot no. 20,21,22 of S.No 58t3B demarcated by its boundaries (latitude and longitude of the end points)_ to the North_ to the South_ to the East to the West of Division-NASIK ,village-Satpur,Taluka-NASlK, District-NAStK ,PlN: 422222 admeasuring 1115.00 sq.mtrs. area being developed by I- M/S Gokul Infrastructure. M/S Pooja Kutir Nirman Pvt. Ltd., M/S Rajendra M. Developers & BuiHers Pvt. Ltd l Reference: MahaRERA Registration Number- P51600002109 Sir, I Rohan.K.GuMARE have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to in-situ or in the authorized fiI,il:l'};rfX;totestlns raboratory and to ensure 1. Material Testins:_ fo'owins mandatory checks iii;i"ilirlfrSjjed on the basic mareriats, used in i. Cement- It has been tested for its fineness., compressive strenoth etc. soundness, setting time, as pr rs _ or J' as pe' industry "oo!'5iis,rgso as per other.rebvant itJ,:l*t-?",,H't and its resurts are within rhe ii. Coarse aggregate _ 't""d;;;. It has been tested, for^deleterious ,"t^"111:,,,clay value, impact value as per lS .lumps, crushing 2430116; ;;; per other retevant o,. as per industry ts/BstNBc l';?,: standards it"'rirrts are within the permissibre "nc iii. Bricks/ btocks _ They have been tested for water absorption, crushing strength etc. as per rs s454:r978 or as per,.otner rerevani Glisl^rec standards and its results are within p"rri""i-Of" or'""-ilr'inou"try ".i0" firit", iv. Concrete/Ready-mix Concrete_ It has been tested for compressive strength f9r._grlous periods as per 15456:2000 and tS 11ee industry standards and its or;;;;;#,.1#vant tS/BSrNBi;"1;" as per ritn'r'i"=r*i"sibre rimits. '.""uii"Li" v. Steel for concrete- ft has been tested as per rs 2062:2011 0r lslBS/NBC code or as per..industw as per other rerevant rt""o"Jr ior tensire strength, and gauge length etc. and its resulis ,o *itnln permissible limits. erongation vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and and sanitary fittings {ittings, prpes arr itemsl"usecr in this project conform y#5::i:l[:?:j:r" "t"^.,1l1"i_grt code or as per standaios raic oown oyine-rno,IJt,y ro,. 2. Workmanship:- l/.we hereby certify that work has been carried out under our supervision. we further certify that workmanship and quality is satisfactory Lp to m" mark and the work has been acceptable wiinin tne permLsible "no limits of deviations as per relevant code of oractice. 3. Electrical Materials and workmanship: - works of all the electrical wiring/connections/lift installationiother electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materialJused conform to the relevant LS/ B.s/ National Building codes or as per industry standards. 4. Structural engineer: - A promoter has engaged structural engineer Mr.Dilip Gadakh having Licenses no. having office no - cell no The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying pcc for foundation in consultation with soil consultant. The formwork and c6ncrete mix design has been done as per ls 10262:200g or as per other relevant codes as applicable. His periodic checks and certificates for STABlLlry and sAFETy have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of works which were not conforming to the standard specifications and which were not rejudged. Yours Faithfully, Sisnature of Ensineer,f$p-'*"r, il*.t$#i#'$il:$ffi ti':I"::Tif orn Place: Nasik