FORM-2A I See MahaRERA o.der no. of 20181 ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, M/S Vaastu Reallors Plot no. '1, Thorat Petrol Pump, Kalanagar, Jail Road, Nashik Road, Nashik 422101 Qualitv Assurance Certificate (Certificate norfor the quafter ending up to -301091201q Subject : Certificate for quality of materials used and quality of Construction and workmanship for the Work of 2 No. of Building(s) of the project situated on the plot bearing C. S. No./C.T.S. No./ Survey No./Final plot no. 3, 4, 5 and 7 demarcated by its boundaries (latitude and longitude of the end points) Cantonment road to the North Survey no. 74 E&D to the South Cantonment open space to the East part of Survey no 74A & 748 to the West of Division Nashik village Nashik taluka Nashik District Nashik PIN 422401 admeasuring 7185 sq.mtrs- area being developed by Vaastu Realtors. Reference: MahaRERA Registration Number- P51600004723 Sir. I Rahul Mali have undertaken an assignment of supervision of this real estate project. l. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate o, superuision of work and to carry out material testing in-situ or in the authorized Iaboratory and to ensure quality of work and l. Material Testino :- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant |S/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate * li has teer tested, for deleterious materials, clay lumps, c.ushi.tg value, ampact value as per lS 243011986 or as per other relevant IS/BS/NBC code or as per industry stardards and its.esults a.e within the pe,missible limits. i i:. Bricks/ blocks - They have teen tested for water absorption, crushing streng:h etc. as per :S 5454:1978 or as per other,elevani lS/85/NBC code or as per industry standards and its resu,ts are within permissible limits. iv. Concrete/Ready-mix Concrete- It has been tested for compressive strength ior various periods as per 15 456:2000 and lS 1199 or as per other relevant lS/BSINBC codes, as per industry standards and ats results are within permissible limits. v. Steel for co.crete- It has been tested as per lS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strengt!, elongation and gauge length etc. and its resulis are wiihin permissible llmits. vi. Testing of Other materials Other materials lake sand, crushed sa.d, floo. tiles, fixtures and {ittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant lS/BS/NBC code or as per standards laid down by the lndustry for a part:cular material. 2. Workrhanslrip:- li we hereby certify that work has been ca..ied out under our supervision. We further certify that workmanship and quality is saiisfactory and up to the mark and the work has been acceptable within lhe permissible limits of deviations as per releva.li code of practice. 3. Electrical Materials and workmanship: - works ol all lhe electrical wiring/connections/liIt !nstalla:ion/other electrical installations have been carried out under authoized/registered electrical erg;neer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per andustry standards. 4. St.uetural engineer: - Promoters has engaged struc:u.al engineer Mr.Achal Raie having Licenses no. 11 havang otfice .to 0253 - 2465975 .- cell no 9823159721 The st.uctu.al design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultatior wittr soil consultant. The formwork and concrete mix des:gn has been done as per ls 10262:2009 or as per othe. relevant codes as applicab:e. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or lor the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming lo the standard specifications and which were not rejected. .L [,tt--. t'-1 Yours Faithtully, Signature of Engineer (Site Supervisor) Name: Rahu Ma‖ License no.(if any) Phone no. 9689592120 Place: Nashik