Ar. SURESH N. PATEL ASSOCIATES No. 1,2, Shubhankar Vastu Ph. : (0253) 2508226 Date:oglor/aorr TO, M/S J.P. BUILDER,S AND LAND DEVELOPERS, SUBJECT: CERTIFICATE OF PERCENTAGE OF COMPTETION OF CONSTRUCTION WORK OF PROPOSED PRO]ECT NAMED J.P.PARK, BUILDING NAME IMAHARERA REGISTERATION NUMBER] SITUATED ON THE PLOT BEARING SURVEY NO. '.P.PARK + 3tlLl2l2l4 FINAL PLoT No tLluzlzlt 1+2+3+4+5, DEI/]ARCATED BY ITS BOUNDARIES (LATITUDE AND LONGITUDE OF THE END POINTS) 12MTRoADToTHENORTH,oPENsPAcEToTHESoUTH,gMTWIDERoADToTHEEAST, SURVEY. NO 371!/2lL To THE WEST, VILLAGE-MAKH MALABAD TAIUKA-NASHlK DISTRICT-NASHIK ptN 422003 ADMEASURING 2807.8? SQ.MTs. AREA BEING DEVELOPED BY PROMOTER'S NAME M/S J.P. BUILDER,S AND LAND DEVELOPERS. 5rR, I AR. SURESH PATEL HAVE UNDERTAKEN ASSIGNMENT A5 AN ARCHITECI OF ONLY CERTIFYING PROPOSED PROJECT NAMED J'P'PARK' PERCENTAGE OF COMPLETION OF CONSTRUCTION WORK OF J.P.PARK BUT I ACKNOWLEDGE THAT IN NO EVENT SHALL I OR MY FIRM BE LIABLE BUILDING NAME ALREADY EXISTING STRUCTURE WHICH FOR ANY MISHAP DIRECTLY OR INDIRECTLY ARISING OUT OF BEARING SURVEY NO.TLlLlzl2lL ls NOI D[srGNLD AND APPROVED BY ME,sITUATED ON THE PLOT +3||L/2/2/aF|NALPLoTNo.l+2+3+4+5,oFD|V|5|oNNASHIKTALUKANASHIKD|STR|crNASH|K AREA AS PER APPROVED PLAN IS PIN 422003 ADMEASURING 2807'87 SQ.MTS. EXISTING BUILTUP L22S.STSQ.MANDl5Tg,OOSQ.MISDESIGNEDANDAPPROVEDBYMYFIRMANDDEVEIOPEDBY 2.FoLLoWINGTEcHN|cALPRoFESS|oNALSAREAPPoINTEDBYoWNER/PRoMoTER:. i MR sURE5H PATEL As Architect (For Proposed Work) ll. MR SUNIL PATEL As Structural Consultant (For Proposed Work) 3'BASEDonS|TEINSPECI|oN,W|THRESPECTToTHEBUILD|NGoFTHEAFoRESA|DREATESTATE THE PERCENTAGE OF WORK DONE PROJECT, I CERTIFY THAT AS ON THE DATE OF THIS CERTIFICATE, FoRBUILD|NG|SASPERTABTEAHEREINBELoW.THEPERCENTAGEoFWoRKEXECUTEDW|TH RESPECTToEACHoFTHEACT|VITYoFTHEENTIREPHASE|SDETA|LED|NTABLEB. TABLE A BUILDING :J.P.PARK SR.NO TASK/ACTTVtW PERCENTAGE OF WORK DONE 1__ Excavation t00% 2___ 0 No. Of Basements And plinth 3__ _U No. Ut_Podtums NIL 4 1 Stilt Floor (pailine + Shopt NIL 5 2 Number Of Slabs Of Super Structure 100% 6 Internal Walls, Internal plaster, Floorings Within 1,00% Flats/Premises,Doors And Windows To Each Of The Flat/Premises 7 Sanitary Fittings Within The Flat/ premises, Electrical 100% Fittings Within The Flat/ Premises 8 Staircases, Lift Wells And Lobbies At Each Floor Level Connecting Staircases And Lifts, Overhead And !l 49Is'g111!]rygletra n ks. 9 I ne txternat Plumbing And External plaster, Elevation, rc0% Completion Of Terrace With Water proofing Of The Building/Wings 10 Installation Of Lift, Water proofing, Fire Fighting Fittings And Equipments As per CFO NOC, Electrical Fitting To Common Area, Electro .Mechanical Equipments, Compliance To Conditions Of Environment / CRZ NOC, Finishing To Entrance Lobby, plinth protection, paving Of Areas Appurtenant To Building Compound Wall And All Other Requirements As May Be Required To Be Obtain Occupation/ Completion Certificate. TABLE B INTERNAL AND EXTERNAL DEVELOPMENT WORK WITH RESPECT OF THE ENTIRE REGISTERED PHASE. SR.NO COMMON AREAS AND PROPOSED PERCENTAGE OF DETAILS FACILITIES, AMENITIES (YEs/No) WORK DONE 1 Internal Roads And Floor NO Paths 2 Water Supply YES 100% NMC Sewerage (Chamber,Lines, YES 100% Septic Tank) A Strom Water Drains NO Landscaping And Tree YES L00% TREE PLANTING Planting 6 Street Light NO Community Buildings NO 8 Treatment And Disposal Of NO Sewage And Sullage Water I' Solid Waste Management And Disposal NO 1U Water Conservation, Rain NO fry+qlerystLle-- 11 Energy Management NO 1-2 Fire Protection And Fire NO Safety Requirements t I rt rtecrncat Meter Room, sub NO I Sta_tiqn, Rece iving Statio n 74 NO YOUR'S FAITHFULLY, AR. SURESH PATET MAVANI ASSOCIATES (LlcENsE NO.CA/20041327s3) __ ITIAVAIVI ASSOCIATES AR.-SURESH N. PATEI-, s H o XNES 1T; .",fi f,X'^i{H ?i. .-DHAVALGIRI SOCIETY. K,ATHE GALLI, NASHIK.3. *