MANOJ KALA & ASSOCIATES B 301, 302 Space Olympia, Sutgirni Chowk, Garkheda, Chh. Sambhaji Nagar 43100t Contact: +91 9637005781 I me1_o_|. kalA@ycho! ss r! * Annixure A {ronm r lsee Regulation 3l ARCHITECT'S CERTIFICATE (To be submitted at the time of Registration of Ongoing Project & for Wthdrawal of ivloney from Designated Account) Date 20-10-2024 To, The SWIFT Engineering Company Private Limited, Plot No, E-321A-2, Chikalthana MIDC, Aurangabad. Sublect: Certificate of Percentage of Completion of Construction Work of Fortune Prospera having MahaRERA Registration Number P51500077300 being developed by SWFT Engineering Company Private Limited. Sir, I / We have undertaken assignment as Architect / Licensed Surveyor of Certifying Percentage of Completion of Construction Work of Fortune Prospera having MahaRERA Registration Number P51500077300 being developed by SWIFT Engineering Company Private Limite# Baseci on ihe Site lnspection, with respect to the Layout / each BuildingA&ing of the aforesaid Real Estate Project, I certify that as on date of this Certificate, the Percentage cf Work Done for each of the BuildingAffing of the Real Estate Project under MahaRERA is as per Table-A herein below. The percentage of work executed with respect to each of the activity of entire Phase is detailed in Table-B. TABLE-A Buildino A of Fortune Sr. Tasks / Activity Percentage ol Actual No. Work Done (As on date of the Certilicate) (1) (2) (3) 1 Excavation 100 2 X number of Basement(s) and Plinth 50 a X number of Podiums 0 4 Stilt Floor tr X number of Slabs of Super Structure 0 o lnternal walls, lnternal Plaster, Floorings within 0 Flats/Premises, Doors and Windows to each of the Flat/Premises 7 Sanitary Fittings within the Flat/Premises, Electrical U Fittinqs within the Flat/Premises I Staircases, Lifts Wells and Lobbies at each Floor 0 level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 9 The external plumbing and external plaster, 0 elevation, completion of terraces with waterproofing of the Building/Win g 10 lnstallation of lifts, water pumps, Fire Fighting 0 Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Buildingffling, Compound Wall and all other requirements as may be required to Obtain Occupation lCompletion Certificate TABLE.B Common Areas (lnternal & External Development Works) Building A of Proiect Fortune Prospera s. Common Areas & Proposed Percentage Details No. Facilities (Yes / of actual NO) Work Done (As on date ol Certilicate) (1) (21 (3) (4) (s) 1. lnternal Roads & Yes 0 INTERNAL PHOJECT TAR Footpaths : OR CEMENT ROADS 2. Water Conservation, YES 0 RAIN WATER HARVESTING Rain water Harvesting AS PER NORMS 3. Energy management : NO 0 NA 4. Fire Protection And YES 0 AS PER FIRE NORMS Fire Safety Requirements : q Electrical Meter YES 0 AS PER MSEB NORMS Room, Sub-Station, Receivinq Station : b. Aggregate area of NO 0 NA recreational Open Space : -7 r)^an Darkin.r ' YES U AS PER DRAWING 8. WaterSupply: YES 50% FROM BORE-WELL AND FROM MIDC o Sewerage (Chamber, YES 0 DRAINAGE LINE TILL MIDC Lines, Septic Tank , LINE STP): '1 0. Storm Water Drains : NO 0 NA 1l. Landscaping & Tree YES 0 INTERNAL PROJECT TREE Plantinq : PLANTATION 12. Street Lighting : YES 0 INTERNAL PROJECT STRET LIGHTS 13. Community Buildings NO 0 NA : 14. Treatment And NO 0 NA Disposal Of Sewage And Sullaqe Water : 1E Sclid Waste NO NA Management And Disposat : Kala) Architect Agreed & Accepted by: Swift Engineering Co PvL lld, Signature of Promoter liame: SWIFT Engineering Company Private Limited Dalet20-10-2924