Annexure A FORM 1 lSee Regulation 3l ARCHITECT'S CERTIFICATE (To be submitted at the time of Registrartion of Ongoing Project & for Withdrawal of Money from Designaled Account) Dale. 12-07 -2024 To, SAI SHRADDHA BUILDCON, 02, NEAR JAIHIND PUBLIC SCHOOL, CAMBRIDGE JALNA ROAD, AURANGABAD Subject: Certificate of Percentage of Completion of Construction Work of RANA PARK having MahaRERA Registration Number P51500055064 being developed by SAI SHRADDHA BUILDCON. (For Apr to Jun 2024 QPR) Sir, I / We MIRKUTE ARCHITECT AND INTERIOR DESIGNERS have undertaken assignment as Architect / Licensed Surveyor of Certifying Percentage of Completion of Construction Work of RANA PARK having MahaRERA Registration Number P51500055064 being developed by SAI SHRADDHA BUILDCON. Based on the Site lnspection, with respect to the Layout / each BuildingiWing of the aforesaid Real Estate Project, I certify that as on date of this Certificate, the Percentage of Work Done for each of the BuildingArVing of the Real Estate Project under MahaRERA is as per Table-A herein below. The percentage of work execuled with respect to each of the activity of entire Phase is detailed in Table-B. TABLE-A Number FOR RANA PARK - Buil A S. Tasks / Activity Percentage of Actual No. Work Done (As on date of the Certificale) (1) (21 (3) 1 Excavation 100% 2 X number of Basement(s) and Plinth 100% 3 X number of Podiums 4' Stilt Floor 100% 5 X number of Slabs of Super Structure 1000/, 6 lnternal walls, lnternal Plasler, Floorings within Flats/Premises, 80% Doors and Windows to each of the Flat/Premises 7 Sanitary Fittings within the Flat/Premises, Eleclrical Fittings within 10% the Flat/Premises B Stajrcases, Lifts Wells and Lobbies at each Floor Ievel connecting 0% Staircases and Lifts, Overhead and Underoround Water Tanks. 9 The external plumbinq and external plaster, elevation, completion ook of terraces with waterproofing of the Buildingl/Ving 10 lnstallation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas. 0% l electro, mechanical equipment, Compliance to conditions of environmenl /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building,A/Ving, Compound Wall and all other requirements as may be required to Obtain Occu /Com Certificate TABLE.A Build Numnber FOR RANA PARK - Buildi n S. Tasks / Activity Percentage of Actual No. Work Done (As on date of the Certificate) (1) (3) 1 Excavation 100% 2 X number of Basement(s) and Plinth 100% 3 X number of Podiums 4 Stilt Floor 100% 5 X number of Slabs of Super Structure 100% 6 lnternal walls, lnternal Plaster, Floorings within Flats/Premises, 80% Doors and Windows to each of the Flat/Premises 7 Sanitary Fittings within the Flat/Premises, Electrical Fittings within 1Oo/o the Flat/Premises -8 o% Staircaies, t-ltts Wetts inO Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. I The external plumbing and external plaster, elevation, completion 0% of terraces with waterproofing of the Building/Wing 10 lnstallation of lifts, water pumps, Fire Fighting Fittings and o% Equipment as per CFO NOC, Electrical iittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing lo entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate TABLE.B Common Areas (lnternal & External Development Works) FOR RANA PARK S. Common Areas & Facilities Proposed Percentage of Details No. (Yes / NO) actual Work Done (As on date of Certificate) (1) (21 (3) (4) (5) 1 lnternal Roads & Footpaths : YES o% lnternal Project Roads Cement Road 2 Water Conservation, Rain water YES 0% Rain water Harvesting as Harveslino: per Norms 3. Enerqv manaoemenl : NO NA 4. Fire Protection And Fire Safety NO NA Requirements: 5 Electrical Meter Room, Sub- NO NA Station, Receivino Station : 6. Aggregate area of recreational YES o% As sanction Plan Open Space : 7 Open Parkinq : NO NA 8. Water Supply : YES o% From Bore-well 9. Sewerage (Chamber, Lines, YES 10% Drainage Line Septic Tank , STP) : 10. Storm Water Drains : NO NA 11. Landscaping & Tree Planting : YES 0% Tree Plantation in Open Space 12. Street Lighting : YES Oo/o lnternal Project Slreet Liqhts 13. Community Buildinqs : NO NA 14. Others (Option to Add more) NO NA Yours fa ithfully, FOR MIRKUTE ARCHITECT AND INTERIOR DESIGNERS f,".j'r*L-' ARCH. SAURABilT,,lINXUTC lco,"lijt Signature & Name (lN BLOCK LETTERS) Architect License Number CAl2017 / 86766 . Agreed & Accepted by: .tBM"t- -@M Signature of Promoter Name: SAI BUILDCON Date: 1 /.r?-<( ff,, *,^ \