R. S. JADHAV ARCHITECT A-306, CITIUS, SPACE OLYMPIA, NEAR GARKHEDA STADIUM SUTGIRNI CHOWK, GARKHEDA, AURANGABAD - 431 005 INDIA CONTACT: +91 7875558825, e-mail : jbandassociate1@gmail.com J.3, ASSOEIATE ARCHITECT, INTERIOR, DESIGNER & VALUER FORM 1 (See Regulation 3] ARCHITECT'S CERTIFICATE (To be submitted at the time of Registration of Ongoing Project & for Withdrawal of Money from Designated Account) Date: 30/09/2023 To, VA Developers, A-306,Citius, space olympia, sut Girni chowk, Garkheda Aurangabad Subject: Certificate of Percentage of Completion of Construction Work of "ARYAN HILLS" Plot No-45 TO 50, Gut No-347/1 situated at satara Aurangabad having MahaRERA Registration Number ( P51500050782 ) being Developed by Shri - Deepak Gangadhar Aher. And Shri - Prakash Gangadhar Aher through GPA V A Developers partner Shri. Vishal Rajaram Jadhav and other Sir, 1/We have undertaken assignment as Architect/ Licensed Surveyor of Certifying Percentage of Completion of Construction Work of "ARYAN HILLS" Plot No-45 TO 50, Gut No-347/1, situated at satara Aurangabad having MahaRERA Registration Number (P51500050782) being developed by Shri - Deepak Gangadhar Aher. And Shri - Prakash Gangadhar Aher through GPA VADevelopers partner Shri. Vishal Rajaram Jadhav and other. Based on the Site Inspection, with respect to the Layoutleach Building/Wing of the aforesaid Real Estate Project, Icertify that as on date of this Certificate, the Percentage of Work Done for each of the BuildingWing of the Real Estate Project under MahaRERA is as per Table-A herein below. The percentage of work executed with respect to each of the activity of entire Phase is detailed in Table-B. SADHAV qALA.M.C.A Reg.No. CAI10/4C967 TABLE-A (Building A1 TO A11) S. Tasks / Activity Percentage of ActualWork No. Done (As on date of the Certificate) (1) (2) (3) 1. Excavation 100 %. 2. Basements (if any) 3. Podiums (if any) 4. Plinth 5. Stilt Floor 6. Slab of Super Structure 7. Internal Walls, Internal Plaster, Floorings, Doors, windows within Flats / Premises 8. Sanitary Fittings wthin Flats/Premises olc 9. Staircases, Lift Wells & Lobbies at each Floor Level Overhead and Underground Water Tanks 10. External Plumbing & External Plaster, Elevation, Completion of Terraces, with waterproofing of the Building /Wing 11. Installation of Lifts, Water Pumps, Fire Fighting Fittings0 and Equipments as per CFO NOC, Electrical Fittings, Mechanical Equipments, Compliance to conditions of Environment / CRZ NOC, Finishing to Entrance Lobby/s, Plinth Protection, Paving of Areas appurtenant to BuildingWing, Compound Wall and all other requirements as may be required to complete Project as per specifications to Agreement of Sale, Any other Activity SADHAD Reg.No. CAIM0/48967 CHITY TABLE-A (Building B1 TO B11) s. Tasks IActivity Percentage of Actual Work No. Done (As on date of the Certificate) (1) (2) (3) 1. Excavation 100 %. 2. Basements (if any) 3 Podiums (if any) 4 Plinth 100 % 5 Stilt Floor 6 Slab of Super Structure 90% 7. Internal Walls, Internal Plaster, Floorings, Doors, 45% windows within Flats /Premises 8. Sanitary Fittings within Flats / Premises 0 9 Staircases, Lift Wells & Lobbies at each Floor Level 30% Overhead and Underground Water Tanks 10. External Plumbing & External Plaster, Elevation, 0 Completion of Terraces, with waterproofing of the Building / Wing 11. Installation of Lifts, Water Pumps, Fire Fighting Fittings 0 and Equipments as per CFO NOC, Electrical Fittings, Mechanical Equipments, Compliance to conditions of Environment / CRZ NOC, Finishing to Entrance Lobby/s,Plinth Protection, Paving of Areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete Project as per specifications to Agreement of Sale, Any other Activity TABLE-B Common Areas (Internal & External Development Works) in respect of the Registered Phase / Project Number S. Common Areas & Facilities Proposed Percentage of Details No. (Yes /No) actualWork Done (As on date of Certificate) (1) (2) (3) (4) (5) 1. Internal Roads & Footpaths No Cidco Approved layout 2. Water Supply Yes Bore well 3. Sewerage (Chamber Lines, Yes AMC chamber line Septic Tank, STP) 4 Strom Water Drains No T/AJI MCAUn Reg.No. CAI10/40967, RCHI 5 As per Amc norms Landscaping &Tree Planting YES 0 6 Street Lighting No 7. Community Buildings No 8 Treatment &Disposal of Sewage No and Sullage Water 9 Solid Waste Management & No Disposal 10. Water Conservation / Rain Water Yes Harvesting 11. 0 Energy Management No 12. Fire Protection & Fire Safety No 0 requirements 13. Electrical Meter Room, Sub- No 0 Station, Receiving Station 14. Others (Option to Add more) No AJLA.M.C.A Yours faithfully, Reg.No. CAI10/48967 Signature & Name (in block letters) Architect Jadhav RS License Number Agréed &Accepted by: Signature of Promoter Name: VA Developers Date:30/09/2023