An. SANJAY s. so;xAn Mobile no : 9822012757 \- ,!- sp ? C € architects & Associates Larrdscape Desigl-)*r' .- Architect, ll11e rio r & O SDrce Ardlltech & Associates ;fni"i.*',pr.'t no.rS'eh"gy, NagEr.Aumageb8d43l 00 I Emaili oBpeearcMecb@gmail-com FORM 1 lsee Regulation 3] ARCHITECT,S CERTIFICATE Date r 30/06/2025 to, The Kashi Gopal Park, Gangapur, Aura ngabad-431109 of Construction Work of Subject : certificate of Percentage of completion I No. of Building(s)/---- Wing(s) of the-A1-Phase situated on the of tfre projea IfrlahaRERA Registration Numberl ;i";;;";;a.'*. No/crs No'fSurvev No'/ Final Plot No'-G'ut No'307/3/Al end d".rr..t"i by its boundaries (latitude and longitude of theGangapur'Dist'Chhatrapati sambhajinagar- points), Gut No.3o7l3/A ,Gangapur Vaijapur Road'Taluka. developed by Kashi Gopal Park 431109,admeasuring 265s sq'mis' area being Sir, as Architect /Licensed Surveyor ol l/ We Ar'Sanjay Sonar have undertaken assignment Work of the 1 Building(s)/ certifying Percentage of Completion of Construction 1 Phase ot itre project' situated on the plot bearing C'N' No/ -A1 Wing(s) of the No.SOzll/A,Gangapur Vaijapur Road'Taluka cTS No./Survey No./Final Plot No-). eui developed 431109'admeasuring 2555 sq'mts' area being Gangapur,Dist.Chhatrapati Sambhajinagar- bv Kashi Gopal Park 1. Following technical professionals are appointed by owner / Promoter :- (r) M/s/Shrr/Smt. Ar.Saniay Sonar as L'S' / Architect ; iiif ni/i itt'r' it.t. Er. chaitnava thalerao as structural-consultant iiii) wtl, /sf,rl / stt. *------ as MEP consultant iiui rv/, /sfrri / stt.;------ as Site supervisor BasedonSite|nspection,withrespecttoeachoftheBui|ding/WingoftheaforesaidRea| .rir certificate, the,Percentageof work done for Estate project , I certify that as ;^ii" i.," "t registered ,nl, building/wing of the Real Estate Project as Y9: 1T:,:l "..i "t percentage or the work executed with :lil:il];':#il i:'J;J|.;;ilof the entire phase is detailed in Table B' A herein berow' rhe resoect to each of the activity L TABLE-A of the Building /Wing N u m ber---41-(to be prepared separately for each Building /Wing Sr. No. Tasks /Activity Percentage of work done Excavation LOOYo 1. 2. 1- number of Basement(s) and Plinth too% 3. O number of Podiums NA 4. 1 no. of Stilt Floor OYo 5 of Slabs of Super Structure O%6 -3-number OVo 6. Internal Walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises. Sanitary Fittings within the Flat/Premises, o% Electrical Fittings within the Flat/Premises. staircases, Lifts Wells and Lobbies at each o% 8. Floor level connecting Staircases and Lifts, o% Overhead and Underground Water Tanks. o% q The external plumbing and external plaster, o% Elevation,competion,Terrace with waterproofing of the Building/Win8. 10. l^IJlrtio^ liftt *.t"t prmps, Fire Fighting OYo "f Fittings'and Equipment as per CFO NOC, Electrical fittings to common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRz NOc, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, compound Wall and all other requirements as may be required to obtain Occupation / Completion Certificate 3 TABLE-B Works in respect of the entire Building /Wing Number--.151-('*t'"tf tiO External Development Registered Phase. Ercentage of Details Common areas and Proposed Sr. No. Work done E..ilifip< (Yes/No) Oo/o Yes lnternal Roads & E^^lhneths. Yes o% Water SuPPIY : OYo Yes 3. Sewarage (chamber, lines, Septic Tank , I srP). OYo Yes 4. Storm Water Drains OYo LandscaPing& Tree NA J. Planting' '. OYo Yes 6. I Street Lighting I Oo/o NA I CommunitY Buildings '-f-Tr".tt"nt and disposal NA OYo d. of sewage and sullage I lwater. OVo NA 9. Solid Waste management & NA o% 10. Water conservation, a:in water harvesting' NA o% II, Energy management -.--..-.----.--. NA o% L2. Fire protection and fi.a