fl YOGESH ZAVAR B.Arch., M.C.A., A.l.l.A Itl lrr Architects Interior designers Reg.No. CA,/98/23394 lll Landscape designers CONCEPTS C+2, D -Wing, First Floor, Bharat Bazar, A.P.l. Corner, Aurangabad. Mobile No. 992567e74e \rririteci..l _ 1, _;r .laj: iq I il rli r ,'lt rlFtrcitetlr Annexure A ,. il ;.. . FORM T [See Regulation 3] ARCHITECT'S CERTIFICATE (To be submitted at the time of Registration of ongoing project & for withdrawa] of Money from Designated Account) Datei 02.04.2024 To, Preetansh Developers, Aurangabad subject certificate of percentage of completion of conshuction work of KINGS clry having, Registration Number ps1soo04s884 being oevetopeJ-uy-'eieeiansn , y_1tREM ueveto0ers. Sir, | / We have undertaken assionment as Architect / Licensed Surveyor of Certifying percentage of completion of conshuction woit< ot xtrcs clrY having rv.n.iinn Registration Number ps15ooo4s884 being Developed by preetansh Developers. Based on the site Inspection, with respect to the Layout i each BuildingMing of the aforesaid Real Estate lrgjecl I certify that as on date of this certificaie, the percentage of work Done for each of the BuildingMing of the Real Estate projectrnder MahaREM is as per Table-A trerein betow. ihe pri.*ugu of work executed with respect to each of the activity of entire phase is detaired in Tabre-B. iT Layout -/ Buirding / wing Number KtNGs ;flAEitirailg (to be prepared separatery for each LayouVBuildingAfi ing of project) S. No. Tasks / Activity Percentage of Actual Work Done (As on date of the Certificate) (1) l2l (3) L Excavation 100o/o 2. Basements (if anv) NA Podiums (if any) NA L PIinth 1000 Stilt Floor ;o. Slab of Super Structure 100V0 100% Internal Walls, Internal plaster, Floorings, Doors, windows 1000/o within Flats / Premises 8. Sanitary Fittings tlthin Flats / premises 100V0 9. Staircases, Lift Wells & Lobbies at eachJtoorTwel Overhead 1000/o and Underground Water Tanks 10. External Plumbing & External plaster, Elevation, Compleiionii 1000/o Terraces, with waterproofing of the Buildino / Wino 11. lnstallation of Lifts, Water pumps, Fire Fighting Fittings and 100V0 Equipment's as per CFO N0C, Electrical Fittings, Mechanical Equipment's, Compliance to coiditions of Environment / CM NOC, Finishing to Entrance Lobby/s, plinth protection, paving of Areas appurtenant to BuildingMing, Compound Wall and aii other requirements as may be required to complete project as per specifications to Agreement of Sale, Any other Activitv Layout _/ Building / wing Number KrNGs crry B Buirding (to be prepared separatery for each LayouUBuildingMing of project) S. No. Tasks / Activity Percentage ofActual Work Done (As on date of the Certificate) QI (3) 1. Excavation 1000/o 2. Basements (if any) NA J. Podiums (if any) NA 4. Plinth 100o/o Stilt Floor 00o/o o. Slab of Super Structure 50Yo 7. Internal Walls, Internal Plaster, Floorings, Doors, windows 0070 within Flats / Premises 8. Sanitary Fittings within Ftats / premrses 000/o 9. Staircases, Lift Wells & Lobbies at each Floor Level Overtread 0070 and Underground Water Tanks P 10. External Plumbing & External Plaster, Elevation, Complqtion of 00% Wino \ Terraces, with waterproofinq of the duildinq / 11. Installation of Lifts, Water Pumps, Fire Fighting Fiftings and 00% Equipment's as per CFO NoC, Electrical Fittings, Mechanical Equipment's, Compliance to conditions of Environment / CM NOC, Finishing to Entrance Lobby/s, Plinth Protection, Paving of Areas appurtenant to BuildingMing, Compound Wall and all other requirements as may be required to complete Project as per specifications to Aoreement of Sale, Anv other Activifu Layout / Building / Wing Number KINGS CITY C Building (to be prepared separately for each LayouUBuildingMing of Project) S. No. Tasks / Activity Percentage of Actual Work Done (As on date of the Gertificate) (1) (2) (3) 1. Excavation 100% 2. Basements (if any) NA Podiums (if anv) NA Plinth 100o/o Stilt Floor 100o/o o. Slab of SuDer Structure 10070 7. Internal Walls, Internal Plaster, Floorings, Doors, windows 700k within Flats / Premises 8. Sanitary Fittinqs within Flats i Premises 00% o Staircases, Lift Wells & Lobbies at each Floor Level 0verhead 60% and Underoround Water Tanks 10. External Plumbing & External Plaster, Elevation, Completion of 3070 Terraces, with waterproofinq of the Buildino / Winq 11. Installation of Lifts, Water Pumps, Fire Fighting Fittings and 30% Equipment's as per CFo NoC, Electrical Fittings, Mechanical Equipment's, Compliance to conditions of Environment / CM NOC, Finishing to Entrance Lobby/s, Plinth Protection, Paving of Areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete Project as per specjfications to Aoreement of Sale, AnV other Activitv Common Areas (lnternat & rxternat oevetop#ftitX?3, res\pect ot the Registered phase / project Number 'r S. No. Common Areas & Facilities Proposed Percentage of actual Work Done Details fles / N0) (As on date of Certificate) (1) (21 (3) (4) (s) 1 Internal Roads & Footoaths Yes 0070 z. Water Supply Yes 3070 Sewerage (Chamber, Lines, Septic Yes 300k Tank, STP) I Landscaoinq & Tree Plantino Yes 00% Street Liqhtinq Yes 00o/o 6. Water Conservation / Rain Water Yes 3070 Harvestinq 7. Fire Protection & Fire Safety Yes 300/o requirements 8. Elechical Meter Room, Sub-Station, Yes 30Vo Receivinq Station Overall Project Completed- 70% Yours faithfully, Ar. Yogesh Zavar License Number (CA/98/23394) Name:Preetansh Develooers Datei 02.04.2024