FORM.2A ISee MahaRERA orde, no. o! 20i81 ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site superviso.,s certificate) (To be uptoaded quarterty) To. The Vikas Developers, CTS. No.20310/4, Shri Dnyanesh Arcade, Samarth Nagar, Au rangabad Quali ty Assurance ce rtificate (Certificate no s / a ppoRwat/ol.a fot the quarter ending 30.06.2020) Subject :.Certificate for quality of materials used and qlality of Construction and workmanship for the Work of 1No. of Buitding of the projeci Sai ApOOnWnt situafeO on the Plot bearing Final ptot.ro PLOT NO. )00 CTS N;. 1586/72, 0"r",""t"0 Oy it. 9"_yI:1."^"_{lgtl!{" and,ong[ude ofthe end points) PLOT NO 179i; the Nodh 30 FEEI WIDE ROAD to the South pLOT NO.199 to t'he East 30 FEEl WIDE ROAD to I: -ry::l9t "jPl\ ALrangabad .? y,:ion 431005 -Aurangabad vi age Au,angabad taluka Aurangabad Distrjct admeasuring 448 00 sq.mtrs. area being developed by by l\y'/s. Vikas Developers (prop. Vikas Laxman Chaudhary) [Promoter's Name: Vikas Laxman Chaudhary] Reference: [.4ahaRERA Regjstration Number_ p51SOOO22303 Sir lSiddheshwar Zadage have undertaken an assignment of supervision of this real estaie project. 1. Our Responsibility: - To carry out the work in accordance with ihe development permission and as per the approved plan and submit certificate of supervis;on of work a.rd to carry out materiar testing in-situ or in the authorized laboratory and to ensure quatity ot woiX anO 1. Material Testinq :- l/we, have applied following mandatory checks on the basic materlals, used an the const.uction. i. Cement- at has been tested for its fineness, soundness, setting time, compressive streltgth etc. as per lS code 3535:'1986 or as per other relevant lS7gs/NBC code, or as per industry slandards and i:s results are within the lermissible limits ;i. Coarse aggregate - It has been tested, for deleterious malerials, clay lumps, crush;ng value, impact value as per.lS 243011986 or as per other relevant lS/BS/NBi code or ai per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for waaer absorption, crushing strength eic. as per IS 5454;197g or as per other relevant iS/85/NBC code or as per industry standards and its .esults are within permissjble limits. iv. Concrete/Ready-mix Concrete- It has-been lested ,or compressjve strength for various periods as per 15 456:2000 and lS 1'199 or as per other relevant lS/BS/NBC codes, as per industry'stanJards and its results are within permissible limits. v. Steel for concrete- It has been tested as per 13 2062:2011or as per other relevant IS/BS/NBC code or as per industry standards tor tensile strength, elongation and gauge length etc. and its results are within permiss:ble limits. vi. Testing of Other materiais Other materials ljke sand, crushed sand, floor tiles, fixtures and {fittjngs, ptpes and senitary fittings etc. (Ljst out al] iiems) used in this project conform to retevant lS/BS/NBC code or as per standards Iaid down by the indusiryior a particular materjat. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervjsion. We further certify thal workmanshrp and qualtty ;s satisfactory and up to the mark and the work has oeen acceptabte wtthtn the permlssibie I'mits of deviations as per relevant code practice. of 3. Electrical Materials and workmanship; - works. of all the electrical wiring/connections/lift :nstallation/other electricat installations have been carried out under authorizedlregistered electrical engineer and its records has been maintained. The materiats used ionform to ttre retevini i.Si B.S/ National Building codes or as pe. industry standards. 4. Structural engineer; - ProIoJ:l:-has engaged structurat engrneer Mr. Vikas L.Chaudhary having Licenses no f 126t91 having office na\O24qX2B62A del, na g}22}34rgj of buitdrngs rn th,s protecl has been do.re under hrs supervisior. I1"":l1"Jl-?.l-qi:tg..r He nas cnecked the soil reporr pcc before laying for foundation in consultation wllh soil consultant. The formwork and concrete mix design has been done * pli I" lozOZ,ZoOS or as per other relevart codes as applicab,e. His periodic cnects anO certificates STABILITY and SAFETY have been kept on record.' ior 5- Preservation of records: - resutts of this project have been property kept i. the prescribed l::"^11 _"j rormars and wr be ""11,1:"1 preservedat ieast up to the defect liability period or for the period as required by any other provisior of law or any other item o, works which were not conforming to the 9;^1"":":_"^r-t=ly l:tenats, sranoaro spectftcatlons and wl.ich were not rejected. Ni Yours Faithiuliy, Signature of Engineer (Site Supervisor) Name:Siddheshwar Jadage Phone no.7767800i 92