FORM-2A I See MahaRERA order no. of 2018] ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor,s certificate) (To be uploaded quarterly) To. The Avenuegold Landmarks LLp, Plot No 1 & 2, Gut No 31, ttkheda, Aurangabad. Qualitv Assurance Certificate (Certificate no pS1S00018843 for the quarter ending 3.1"1 Dec"2OiB) Subject :Certificate for quality of materials used and quality of Constructjon and workmanship for the Work of i No. of Building(s)/ 1 Wings(s)'of the Sai paradise ProjeclA,Phase of the project situated on the piot bearing i. b. ruo.lC.f.S. No./ Survey No./Final plot No. 1 & 2,demarcated by its boundaries jlatitude and longitude of the end points) Sai Paradise Project-B to the North, cut No-31 Remaining Land & Gut No_ 33,to the South, Gut No 30 Remaining Land,to the East,Gut No 32 And Road to the West of Division-Aurang abad,village-ltkheda,taluka,Aurangabad, Diskict_ Aurangabad, PIN-431002. Admeasuring-'t 222.95 sq.mtrs. area being devJoped by [Promoter's Name- Avenuegold Landmarks LLp ] Reference: MahaRERA Registration Number- p51 5OOO1 8843. Sir, l/ We have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure qualjty ofwork;nd 1- Material Testinq :- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its-fineness, soundness, setting time, compressive strength etc. as per lS code 3535;1986 or as per other relevant IS/85/NBC code, or as per i;dustry standards and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per rs 243011986 or as per other rerevant rs/BSiNBC code or as per indusiry standards and its results are within the permissible limits. / iii. Bricks/ blocks - I They have been lested for water absorption, crushing strength etc. as pe. lS 5454:1 97g or as per other relevant ls/85/NBC code or as per industry standards and its results are within permissibte limits. iv. Concrete/Ready-mix Concrete. It has been tested for compressive strength for various periods as per 15 456:2OOO and lS '1 199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are wiihin permissible Iimits. v. Steel for concrete- It has been tested as per lS 2062:2A11 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials ljke sand, crushed sand, floor tiles, flxtures and {fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant ISiBS/NBC code or as per standards Iaid down by the industry for a particular material. 2. WorkmanshiD:- l/ we hereby certify that work has been ca(ied out under our supervision. We fu(her certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of nr..ri^6 3. Electrical Materials and workmanship: - works of all the electrical wiring/connections/lift installationiother electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: - Promoiers has engaged structural engineer Mr.Prasad Aphale having Licenses No. E- 229-96,having office No-21,Varad Complex,Behind Rathi Tower,Bijlinagar,Aurangabad- cell No-.982253'1 290. The structural design of buildings in this project has been done under his supervision. He has checked ihe soil repo( before laying pCC for foundation in consultation with soil consuliani. The formwork and concrete mix design has been done as per ls .10262:2009 or as per other relevant codes as appljcable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all iest results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejeded. Yours Faithfully, ,Y- Signature of Engineer (Site S6peVisor) Name: Mr.Suraj Suresh-Salunke License No- Phone N0-9923232317.