l rORM-2A I See MahaRERA order no. of 2018] ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (sile supervisor's certificate) To, ]WS. AVENUEGOLD LANDMARKS LLB PLOTNO. I & 2, GUTNO 3I, ITKHEDA AURANGABAD- 43IOO1 Qualitv Assurance Certificate (Certificate No P51500018753 for the quarter ending 30th Sep 2019) Subject : Certificate for quality of materials used and quality of Construction and workmanship for the Work of 02 No. of Building(s)/ 02 Wings(s) Project of the sAr PARADISE PROJECT B [P51500018753] situated on, Gut No. 31, Plot No I & 2, Itkheda, Aurangabad demarcated by its boundaries ( latitude and longitude of the end points), by its boundaries. To the North - Gut No-29 Remaining Land To the South - Part of Sai Paradies Project A To the East - Gut No 30 Remaining Land To the West - Gut No-32 & Road Gut No. 31, Plot No 1 & 2, Itkleda, Aurangabad, admeasuring 1740.44 Sq.mts for SAI PARADISE PROJECT B Building is being developed by Promoter AYENUEGOLI) LANDMARKSLLP Ref: MahRERA Registration (P51500018753) Sir, l/ we have undertaken an assignment of supervision of this rear estate project. '1. Our Responsibility: - \ To carry out the work in accordance with the deveropment permission and as per the approved plan and submit certificate of supervision of work ano to cirry ouirl'ateriat testing in-situ or in the authorized raboratory and to ensure quafity of work and 1. Material Testinq :- l/we,,have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, seiting time, compressiv. strength etc. as per ls code 353s:r986 or as per other rerevant rs7B5/NBC slandards and its results are within the permissible limits. oir* p"i;"nir.try "o1", ii. Coarse aggregate - It has been tested, for dereterious materiars, cray rumps, crushing varue, impact varue as per.ls 24301 1986 or as per other rerevant rs/BS/NBi code or ui p"r inarrirv.tanoaro. and its results are within the permissible limits. iii. Bricks/ blocks * They have been tested for w_a.ter absorption, crushing strength etc. as per rs 5454:197g or as per other relevant ,s/9s/NBc code or as per inJustry standards and its results are within permissible limits. iv. Concrete/Ready-m ix Concrete- It ha:^been tested for compressive strength for various periods as per 15 456:2000 and ls 1 199 or as per other rerevant rsrBSrNBC codes, as per industry'stanoaros anJ its results are within permissible limits. v. Steel for concrete- It has been tested as per rs 2062:2011 or as per other rerevant rslBS/NBc code or as per industry standards for tensire strength, eiongation and gauge r.ngth1i".-rnd ii, results are wilhin permissible limits" vi. Testing of Other materials Other maierials like sand, crushe.d.sand, floor tiles, fixtures and pipes and sanitary_fittings etc. (List out ail items) used In this project {fittings, cintorii'il'ieLrant lslBs/NBC code or as per standards raid d'own by the indusiryio* particuiar mateiiat. 2. Workmanship:- ll we hereby certify that work has been carried out under our supervision" We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevanl code of practice" 3. Electrical Materials and workmanship: - works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l"S/ B.Sl National Building codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer Mr. Prasad Aphale having Licenses no. E- 229-96, having office no 21,Varad Complex, Behind Rathi Tower, Bijlinagar, Aurangabad.- cell no 9822531290. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consullant. The formwork and concreie mix design has been done as per ls '10262:200g or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved a1 least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. aithfully, Signature of Engi r) Name: Mr. Sri Salunke License no. Phone no. 9923232317