FORM-2A I See MahaRERA order no. of 2O,l8J ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterty) To, Thc Vikas Developers, Shri Dnl rnesh Arccrle,CTS No 203 t 0/. Samaft h Nagar,Aurangabad. 431001 Quali tV As surance Certificate (Certificate no sA/ spaRsH/05 for the quarter ending 30.09.2020) Subject :.Ce(jficate for quality of materials used and qualiay ol Construction and workmanship for tlre Work of 1 No. of Buildlng of the project the Plot bearing No. 16-4, , of cut No. 42, oi Vit;age jtf,fi"o" -fq Snf SpnnSH situated on a o;"j Aurangabad - geT?rc9te.q 9y its bou ndar jes (latitude and longitud-e of the doint.) prot r.ro. t Z to the Nodh'12l\4tr. Wide Road to ihe South ptot tio. 16_8 to the"nO easis ili.. WiOe noaa to Drvrsion Aurangabad ptot bearing No. 16-4, ot cui ilto. ||t_9"^ry:*_:, , +2, or vittug" rrKneoa rq. & Drst. Aurangabad ^ _ area admeasuring 470.48 Sq.[,4eters. for Buildiig Sat Sparsh is being devetoped by lr'l/s. Vikas DJvelopers f"rrrn 1erop-.V-it C ha ud harv "" Reference: N4ahaRERA Registration Number_ p51500016484 Sir I Pawan N. Potarwar have undertaken an assignment of supervision of this real estate project. 1. Ou. Responsibility: - To cary out the work in accordance wjth the development permisslon and as per the approved plan and submjt certificale oi supervision of work and to carry out material testjng in-silu or jn the auihorized laboratory and to ensure quatity ot wtil'anO 1. Maierial Testinq :- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- ]t has been tested for its fineness, soundness, setting tjme, compresstve strengih elc. as per tS code 3535.1986 or as nFr other rerevant tsls!, NBC-;;;;.;; per rndustry standa.ds and tts resurts are w,thil rne permrssrb,e "" ltmits ii. Coarse aggregate - It has been tested, for deleterious materials. clay lumps, crushing value, impact value as per,lS 24301 1986 or as per other retevant lS/BS/NBi o, ,J p"rliOr.try standards a1d tls resLrlts d.e w,th n the permtssjble limils "oO. iii. Bricks/ blocks - They have been tested for water absorptton, crushing strengfh etc as per lS 5454: 197g or as per other relevant tS/85/NBC code or as p"l. injr"t,y 5iO its resutts are within permissible limits. "'r"nO"irJ iv. Concrele/Ready-mix Concrete_ It has^been lested for compressive slrength for various periods as per l5 456:2000 and lS '1199 or as per other retevanr tsi BS/N"BC results are withjn permissible limits "ooer. aiie, inJi.jili"n#os ,no it" v. Steel for concrete- It has been tested as per rs 2062;2011 or as per other rerevant rs/BS/NBc code or as per industry standards for rensite srrength, resulis are within permissible ljmlts. ;";;;rs":;;;,h and its "iongriton "tc. vi. Testing of Other materials Other materials like sand, crushed sand. floor tjles, frxtures and sanrtary^fittings etc. (List out aI items) used i, irri" ptr""t {fittings, pjpes and lS/BS/NBC code or as per standards talct down by iJ"ii., ,o r"r"r"nt the ,o""uyi"i" p"iii"rtar materiat. 2. Workmanshi p:- i/ we hereby certify fl^tat work has been carried out under our supervision. We further ceriify that workmanship and qualrty is satisfactory been acceptable wrthrn the permrssible limits of "nO ,p to tn" ,IIk tne work i,as practice. devi;tions as "ia peiLiJvant coae of 3. Electrical Materials and workmanship: _ works of all tlte electrical wirino/connections/lift instal,ation/other electrical installations have been carried out under iulhorized/reg t"t"r"J;r""tii". i its records has been maintained. The materials used ionform ";s;;;;;;;o to tne ,"teu""niiSi B.S/ Nationa, Buildjng codes or as per indusiry siandards. 4. Structural engineer; _ !r919!9r: fias engaged structural engrneer i\,4r. Vikas L.Chaudhary havins Licenses no. E '26 I I navrng oitice no(0240r2328020 noSri2Ola;g;""-','-'"', "",r -he str-ctural desion of bui,drnos tn fhrs prolecr l.ds been done Jnder his superv,ston He has checreci_lhe soit report b;fore layi;g i,cc fo; f;;;;al;;in";;;;ultation with soir consultant. The formwork and concrete mrx deslgn n"" U""n Oon" p"l. ls 10262:2009 or as per otfier relevant codes as apptrcabte. ilrs periodic .n""1""" S-IABiLITY and SAFETY have been kept on record. 1lJ certificates for 5. Preservation of records; _ Record of all results of thrs projecl have been properly kept in the prescribed .test tormals and will be preserved at teast up to the detect fiiOifity plriojoifor'tne period as required by any other provision of law 6. Please specify maleriars or anv other item of wo* which were not contorming to the standard specifications and which were not rejected. Niit Yours Fajthfulty, Signature of Engineer (Site Supervisor) Name:Pawan N.potarwar- Phone no.99214702i4