FORM-2A (See MahaRERA order No. Of 2018) ENGINEER'S CERTIFICATE FOR QUALITY ASsURANCEE To The JAGRUT SARA ASSOCIATES, SARA SANGAM PHASE 1, PLOT NO. 2, GUT NO. 49 P, WADGAON KOLHATI (CT), AURANGABAD. Quality Assurance Certificate (Certificate No. FORM-2A for the quarter July-2021) Subiect Certificate for quality of materials used and quality of Construction and workmanship for the Work of 3 No. off buildings(s)/ 3 Wings(s) of the JAGRUT SARA ASSOCIATES of the project situated PLOT NO. 2, GUT NO. 49 P, WADGAON KoLHATI (CT), AURANGABAD, demarcated by its boundaries (latitude and longitude of the end points) OTHER PROPERTY to the North, 18 MTR WIDE ROAD to the South, 18 MTR wIDE ROAD to the East, AREA UNDERUNDER DISPENSARY AND LIBRARY AND SF to the West, of Division WADGAON KOLHATI, village WADGAON KOLHATI, Taluka Aurangabad, District Aurangabad, Pin - 431136, admeasuring 5489.70 Sq. Mtrs. area being developed by JAGRUT SARA ASSOCIATES. Reference: - MahaRERA Registration Number - P51500016384. Sir, I MR. NIKHIL BHARUKA have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: To Carry out the work in accordance with the development pcrmission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specification, and as per NBC and or other relevant code of practice. 1. Material Testing: 1/We have applied following mandatory checks on the basic materials, used in the constructions. i. Cement: it has been tested for its fineness, soundness, setting time, other relevant compressive strength etc. as per IS code 3535:1986 or as per within the IS/BS/NBC code o r as per industry standards and its results are permissible limits. ii. Coarse aggregate: it has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BSNBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/blocks: They have been tested for water absorption, crushing strengths etc. as per IS 5454:1978 or as per other relevant 1S/BS/NBC code or as pr industry standards and its results a r e within permissible limits. iv. Concrete/Ready-mix Concrete It has been tested for compressive strength for various periods as per IS 456:2000 and Is 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete: It has been tested as per IS 2062:2011 or as per other relevant 1S/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials: Other materials like sand, crushed sand, floor tiles, fixtures, and fittings, pipes and sanitary fittings etc. (List out all items ) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship: out under our 1/we hereby certify that work has been carried is satisfactory supervision. We further certify that workmanship and quality and up to the mark and the work has been acceptable within the permissible limits off deviations as per relevant code of practice. 3. Electrical Materials and workmanship:- works of all the electrical wiring / connections /lit been carried out under other electrical installations have installation/ authorized /registered electrical engineer and its records has been maintained. National Building codes o r The materials used conform to the relevant I.S/B.S/ as per industry standards. 4. Structural engineer structural engineer Mr. N G Promoters has engaged office No.-0240-2452305 KARKHANE having Licenses No.-AMC-59/89 having cell No. 9823028081 The structural design of buildings in this project haS been checked the soil report before laying PCC done under his supervision. He has consultant. The formwork and concrete for foundation in consolation with soil 10262:2009 or as per other relevant codes mix design has been done as per IS His checks and certificates for STABILITY and SAFETY periodic as applicable. have been kept on record. 5. Preservation of records: have been properly kept in the Record of all test results of this project at least up to the defect liability prescribed formats and will be preserved off law. a s required by any other provision for the period o r period not works which were 6. Please specify materials or any other item off to the standard specifications and which were not rejected. conforming 1:- Coloring, 2:- Aluminum, 3:- Doors & It's Fitting, 4:- Tiles, 5:-CP8 sanitary. Yours Faithfully, a l y k Signature of Engineer Name: - MR. NIKHIL BHARUKA Phone No: 9 5 4 5 5 1 0 4 8 7 Place: Aurangabad.