U '\A R. S. JADHAV ARCHITECT A-306. CITIUS, SPACE OLYMPIA, NEAR GARKHEDA STADIUM SUTGIRNI CHOWK, GARKHEDA, AURANGABAD - 431 OO5 INDIA CONTACT: +91 240 - 2983017, M.:9370591198,7588534485 e-mail : jbandassociatel @gmail.com J.3. A5 ARCHITECT INTERIOR DESIGNER & VALUER RTIFICATN Date: 30 /03 /2018 To, Devanshi Builders and Land Developers, Shop NO 12, Padampura Circle, Aurangabad .431001 Subject - Certificate of Percentage of Completion of Construction Work of " Silver Park " C -Type Building of the Project Silver Park (RERA Registration Number- NA) situated on the Plot no 03 ,Gut no.5211(Part ) Wadgaon Kholathi , Waluj , Cidco , Mahanagar -l , Aurangabad. Demarcated by its boundaries. ( Latitude and Longitude ofthe end points) North - 18 mts wide Cidco main road. South - Gut no a7 (part) of village Wadgaon Kholathi. East - Plot no 02. West - Plot no 04. admeasuring 431.09 Sq.Mts. Area Bearing developed by M/s Devanshi Builders and Land Developers. Sir, I Mr. R.S. Jadhav ( J B Associates) have undertaken assignment as Architect of certifying percentage of Completion of Construction work of the Shaunak Arcade for C-Type Building of the Project Silver Park , Situated on Plot no 03 Gut no. 52ll (Part ) Wadgaon Kholathi , Waluj , Cidco , Mahanagar -l , Aurangabad admeasuring 431.09 Sq. Mts. Area Bearing developed by M/s Devanshi Builders and Land Developers. Following technical professionals are appointed by Owner/ Promoter:- 1)Mr. R.S. Jadhav ( JB Associates Aurangabad) as Architect 2) Mr. A.S.Patil as Structural Consultant. 3) Mr. Vithal A. Dongre as Site Supervisor. Based on Site inspection, With respect to each of the Building of the aforesaid Real Estate Project, I Certify that as on the date of this certificate, the percentage of Work don for each of the building of the Real Estate Project as registered vide number -NA- under RERA is as per table a herein below. The: percentage ofthe work executed ,\ ,.- r.v /v w"^t"/a \'7 with respect to each of the major activity of the "C" building and Overall Percentage of work done with respect to "C" building is detailed in the Table B. TABLE A .C'BUILDING Sr.no. Tasks/ Activitv Percentage of Work done I Excavation 100% 2 I number of Plinth r00% a J I Number of Basement/ Podiums NA 4 I Stilt Floor 100% 5 4 Number of Slabs of super Structure r00% 6 Internal Walls, Internal Plaster, Floorings within Flats/ r00% Premises, Doors and Windows to each of the Flat/premises 7 Sanitary Fittings within the Flat/premises, plectricil Fittings t00% within the Flat/Premises 8 Staircase, Lifts wells and Lobbies at each Floor Level- r00% Connecting Staircase and Lifts, Overhead and Undereround Lift well --- NA --- water Tanks. 9 The external plumbing and external plaster, elevation, r00% completion of terraces with waterproofing of the Building/ Wing l0 Installation of lifts, water pumps, Fire Fighting Fittings and 100% equipment as per CFO NOC, Electrical Fittings to Common Installation of lifts, Fire Areas, electro, mechanical equipment, compliance to Fighting Fittings equipment conditions of environment I CRZNOC, Finishing to as per CFO NOC , electroo entrance lobby/s, plinth protection, paving ofareas mechanical equipment, appurtenant to Building/Wing, Compound wall and all other compliance to conditions of requirements as may be required to Obtain Occupation/ environment /CRZNOC, Completion Certificate plinth protection --- NA --- .:i,;' i-.i.i. , r. . .. ._. --_.-:.:..._i '',1"r.,,i.i, i,i ar .i. !r -i 'I :;".' :; t.,,'';,'n'^' ".' l t i TABLE _ B .C'BUILDING Intemal & External Development work in Respect of the entire Registered phase Sr.No. Common areas and Facilities. Proposed Percentage of Details Amenities (YesA{o) Work done I Internal Roads & Footpaths Yes r00% Only Paved surface /Concrete. No Footpath 2 Water Supply Yes r00% CidcoWater supply / bore well, J Sewerage ( Chamber, Lines, Yes r00% Chamber, Drainage Lines, Septic Tank, STP) Septic Tank, No STp 4 Storm Water Drains No r00% NA 5 Landscaping & Tree Planting Yes t00% As per Drawings/ Details obtained From Consultant 6 Street Lighting Yes r00% As per Drawings/ Details obtained From Consultant Community Buildings No 0% NA 8 Treatment and disposal of No 0% NA sewage and sullage water 9 Solid Waste Management & No 0% NA Disposal 10 Water Conservation, Rain Yes t00% As per Drawing obtained from water harvesting Consultant. ll Enerry management No 0% NA l2 Fire Protection and fire safetv No 0% NA requirements L3 Electrical Meter room, Sub- No 0% NA station, receiving station t4 Aggregate area of recreational No 0% NA open space Faithfully Yours, Name ( Mr. R.S. JADHAV ) Signature & Name ( License No )