Amrish Joshi And Associates Architect 0ff. : Shop No. 52, Gr. Fl. Reg. No. CA-95/18650 Jai Tower Padampura Approved Valuer Rly. Stan. Road, Aurangabad. Regd. No. F-20882 Coll.: 09422706622, E-mail : amrishandassociates@gmail.com FORM 1 ARCHITECT'S CERTIFICATE To, Date:27.05.2023 ASARAM MIS. SHRISAI BUILDERS THRU, ITS PARTNER SHRI NOHINIRAJ BORUDE,MRS SHITAL PRAVIN TAMBDE. AT GAYATRI NAGAR BRIJWADI Taluka AURANGABAD District AURANGABAD Pin -431003 RESIDENTIAL Subject:Certificate of Percentage of Completion of Construction Work of APPARTMENT Building /Phase of the Project {RERA Registration Number-P51500046576) NAGAR, BRIJWADI Taluka situated on the Plot No. 15., GUT No 32/2/PART AT GAYATRI Area Being AURANGABAD District AURANGABAD Pin -431003 Admeasuring 250.80 SQ .Mts. NOHINIRAJ Developed BY M/S. SHRI SAIBUILDERS THRU,ITS PARTNER SHRI ASARAM BORUDE,MRS SHITAL PRAVIN TAMBDE. Sir, IAR. AMRISH JOSHI have undertaken assignment as Architect of certifying Percentage of "SAI SHRDDHA Completion of Construction Work of the RESIDENTIAL APPARTMENT BRIJWADI, Taluka RESIDENCY" Plot No. 15,GUT No 32/2/PART, ATGYATRI NAGAR AURANGABAD District AURANGABAD Pin 443003 Admeasuring 250.80 SQ .Mts. Area Being NOHINIRAJ Developed BY M/S. SHRI SAIBUILDERS THRU,ITS PARTNER SHRI ASARAM BORUDE,MRS SHITAL PRA VIN TAMBDE. GAYATRI NAGAR BRIJWADI Taluka AURANGABAD District AURANGABAD Pin -431003 1 Following technical professionals are appointed by Owner/Promoter: - (i) AR. AMRISH JOSHI as Architect. (ii) ER.PRADEEP MØTE as Structural Consultant. (iii) Mr. R.K.DHANDE as Site Supervisor Based on Site Inspection, with respect to each of the Building/Wing of the aforesaid Real Work done for each Estate Project,I certify that as on the date of this certificate, the Percentage of(PsTODO46S76) PStSO0022467under of the building/Wing of the Real Estate Project as registered vide number SH JOSH CA9S1065o F-20832 APS CHITECT S RERA is as per table Aherein below. The percentage of the work executed with respect to each of the major activity of the Building AWing and Overall Percentage of work done with respect to each Building/Wing is detailed in the Table B Table A Building RESIDENTIAL APPARTMENT"SAISHRDDHA RESIDENCY" Sr. Tasks /Activity Percentage of No work done EXCAVATION 100% 2 ONE NUMBER OF PLINTH 100% 3 ONUMBER OF PODUMS N/A 4 INUMBER OF STILT FLOOR 100% 5 6 NOS. NUMBER OF SLABS OF SUPER STRCTURE 100% 6 INTERNAL WALLS, INTERNAL PLASTER, FLOORING, WITHIN 60% FLATS/PREMISIES, D00RS AND WINDOWS TOEACH OF THE FLATPREMISIES 7 SANITARY FITTINGS WITHIN THE FLATS/PREMISES ELECTRICAL 0% FITTING WITHIN THE FLATSPREMISES STIARCASES, LIFT WELLS AND LOBBIESAT EACH FLOOR LEVEL 75 % CONNECTING STAIRCASES AND LIFT, OVERHEAD AND UNDERGROUND WATER TANKS. THE EXTRENAL PLUMBING AND EXTERNAL PLASTER ELEVATION, 60% COMPLETITION OF TERRACE WITH WATER PROFFING OF THE BUILDING/WING 10 INSTALLATION OF LIFTS, WATER PUMPS, FRE FIGHTING FITTING 0% NAD EQUIPMENTS AS PER CFO NOC, ELECTRICAL FITTING to COMMON AREAS, ELECTRO, MECHANICAL EQUIPMENT, COMPLAINCE TO CONDITIONS OF ENVIRONMENT /CRZ NOC, FINISHING TO ENTRANCE LOBBY'S, PLINTH PROTECTION, PAVING OF AREA APPURTENANT OF BUILDING/WINGS, COMPOUND WALL AND ALL OTHER REQUIRMENTS AS MAY BE REQUIRED TOOBTAIN MRISY CA95/18650 |5 F-20882 4pDaO ECT & 0CCUPATION/COMPLETITION CERTIFICATI OVERALL PERCENTAGE OF WORK DONE OCCUPATION 80% ICOMPLETION CERTIFICATE TABLE-B COMMERISIAL &RESIDENTIAL APPARTMENT Internal &External Development Works in Respect of the entire Registered Phase |S.no Common areas and Facilities, Amenities Proposed Percentage of Details (Yes/No)Work done Intermal Roads --NA --NA MUNCIPAL CORPORATION |&Footpaths |2. Water Supply YES 100 % MUNCIPAL CORPORATION 3. |Sewerage (chamber, NA 100 % |lines, Septic Tank, STP) MUNCIPAL CORPORATION 4. |Storm Water Drains --NA --NA- MUNCIPAL CORPORATION . |Landscaping &Tree --NA-- --NA- -NA- Planting MUNCIPAL CORPORATION 6. Street Lighting --NA- --NA- |Community Buildings --NA- -NA- --NA- 8. |Treatment and disposal of sewage and sullage YES --NA- MUNCIPAL CORPORATION water 9. Solid Waste management --NA- --NA- --NA- |& Disposal 10 Water conservation, Rainwater harvesting YES 0% DEVELOPER |11. Energy management -NA- --NA- --NA 2 Fire protection and fire safety requirements YES --0% DEVELOPER 13 Electrical meter room, sub-station, receiving Yes 0% --NA- |14. Others (Option to Add more) --NA --NA- --NA MRISH AJOSA Yours Faithfully CA9S/18650 F-20882 Ar. AMRISH JOSHI ARCHITa AMRISH JOSHI CA/95/18650