R. S. JADHAV A-306, CITIIJS, SPACE OLYI!'IPIA, NEAR GARKHEDA STADIUI\,] SUTGIRNI CHOWK, GARKHEDA, AURANGABAD - 431 OO5 INDIA CoNTACT: +91 240 - 2983017, i,rl : 9370591198,7588534485 e-majl : jbandassociaiel @gmail com J.3. ASSOEIATE ARCHITECT INTERIOR DESIGNER & VAtU ER Datet 28 | 01 12011 Jo. tr4/s Kamakshi Builders and Land Developers, Plot no 02 ,Pravin Complex , Bhandas Nagar , Jawahar Colony Road, Aurangabad . Subjectr Certificate of Percentage of Completion ofconstruction Work of " Silver Park " A -Type Building and B -Type Building of the Project Silver Park (RERA Regist ation Number- NA) situated onthePlotno 1& 2,Gut no.5211 (Part ) Wadgaon Kholathi, Waluj, Cidco, Mahanaga. -1 , Aumngabad. Demarcated by its boundaries. Nonh -Pafiofcutno52/l & 18mrswide Cidco main road. South - Gut no 47 & 48 (part) ofvillage Wadgaor Kholathi. East - Gut no 48 (part) of village Wadgaon Kholathi & 9 mts wide road. West - Plot no 03. admeasudng 1029.561 Sq. Mts. Area Bearing developed by l'ts Kamakshi Builders and Land Develope$. Sir, I Mr R.S. Jadhav ( J B Associates) have undertaken assignment as Architect ofcertifying percentage of Completion ofconstruction wofk ofthe Sonal Arcade for A type Building & Sheya Arcade for B type Bui lding of the Proj ect Silver Park , Sitlated on Plot no I & 2 Gut no. 5211 (Part ) Wadgaon Kholathi , Waluj , Cidco , Mahamgar -1 , Aurangabad admeasuring 1029.561 Sq. Mts. Area Bearing developed by M/s Kamakshi Builders and Land Developers. Following technical professionals are appointed by Owner/ Promoter! l)Mr. R.S Jadhav ( JB Associales Aurangabad) as Archit€ct 2) Mr. A.S.Patil as Structural Consultant. 3) Mr. Vithal A Dongre as Site Supervisor. r) project, I -Based on Site inspection, With respect to each ofdd Building ofthe aforesaid Real Esrate Cefiify that as on the date ofthis certificate, the percentage of Work don fof each ofthe building ofthe Real Estate Project as registered vide nunber -NA- under RERA is as per table a herein below. The percentage ofthe work executed with respect to each ofthe major activity ofthe "A" building and ,,8,, building and Ovemll Percentage of wofk done with respect ro "Af building and .,B" building is detailed in the Table B. TABLE A .A'BUILDING Sr,no Taskv Acrivity Percentage of Work done I Excavation 090 2 I number ofPlinth 0% I Nunber of Basemer/ Podiums 1 Stilt Floor 5 ,l Number of Slabs ofsuper Structure ov, Intefnal Walls,lntemal Plaster, Floorings within Flats/ 0% Premises, Doors and Windows to each ofthe Flat/Premises ,7 Sanitafy Fitt;ngs within the FlavPremises, Electrical Fittings 0% withir the Flaf/Prenises 8 Staircase, Lrfts wells and Lobbies at each Floor Level 0vo Connecting Staircase and Lifts, Overhead and Underground water Tanks, 9 The external plumbing and extemal plaster, elevation, 0% completion ofterraces with waterproofing ofthe Building Wing t0 Installation oflifts, water pumps, Fire Fighting Fittings and 0% equiprnent as per CFO NOC, Eleclrical Fittings to Common Areas, electro, mechanical equipment, compliance to conditions ofenvifonment / CRZ NOC, Finishing to entrance lobby/s, plinth protectjon, paving of areas apputenant to Building/Wing, Compound wall and allother requi.ements as may be required to Obtain Occupatiod Completion Certificate ;& TABLE A IB'BUILDING Sr,no. Tasks/ Activity Percentage of Work done Excavation 100% 2 I number ofPlinth l00o/" 3 I Number of Basement/ Podiums NA I Stilt Floor 100% 5 5 Number of Slabs ofsuper Structure 100% 6 lntemal Walls, Intemal Plaster, Floorings within Flats/ '70% Premises. Doors and Windows to each ofthe FlavPremises ,7 Sanitary Fittings within the Flai/Premises, Electrical Fittings 600/, within the Flaf/Premises 8 Staircase, Lifts wells and Lobbies at each Floor Level 60% Connecting Staircase and Lifts, Overhead and Underground Lift well -- NA -- \Yater Tanks. 9 The extemal plumbing and external plaster, elevation, '700/o complelion ofteraces with waterproofing ofthe Building/ wing t0 Installation of lifts, water pumps, Fire Fighting Fitiings and Installarion of lifts, Fire equipment as per CFO NOC, Electrical Fittings to Common Fighting Fittings equipment Areas, ,Finishing to entmnce lobby/s, plinth protection, as per CFO NOC , electro, paving of a.eas appurtenant to Building/Wing, Compound mechanical equipment, wall and all other requirements as may be requiredto Obtain compliance to conditioDs of Occupatior/ Completion Certilicate envirorment / CRZ NOC, above work Not Applicable & remaining 50% completed ,-i TABLE _ B .A' & 'B' BUILDING Internal & Extemal Development Work in Respect ofthe entire Registered phale Sr.N Common areas and Facilities, Proposed Percentage: bf Details Amenities (Yesn,Jo) 1 lntefnal Roads & Footpaths Yes jvo Only Paved sufface /Concrete, No Footpalh 2 Water Supply 0% Cidcowater supply / bore well, Sewerage ( Chamber, Lines, 0% Chanber, Drainage Lines, Septlc Tank, STP) Septic Tanlq No STP 4 Stofm Water Drains No NA 'vo 5 Landscaping & Tree Planting Yes 0% As per Drawings/ Details obtained F.om Consultant 6 Street Lighting Yes 0% As per Drawings/ Details obtained From Consultant 'l Communiry Buildings No OYo NA 8 Treatment and disposal of No 0% NA sewage and sullage water 9 Solid Waste Management & No 0% NA Disposal 10 Water Conservation, Rain water 0% As per Drawing obtained from harvesting Consultant. lt Energy management No 0% NA 12 Fife Protection and fire safety No 0% NA 13 Elecirical Meter room, Sub- No o% NA stat;on, receiving station 14 Aggregate area of recreational No 0% NA Faithfully Yours, Nane ( Mf. R S. JADHAV ) Signalure & Name