rfllflI flIIO(ISIII DEslcNtn a ARcHfiEcrs a |NTER|ORS a LANDSCAPf Opp Z P Office, Aurongpuro, Aurongobod 431 001. Ph.: (0240) 2324210 Cell: 9325211945 ARCHITECT,S CERTIFICATE (TobesubmittedatthetimeofRegistrationofongoingProjectandforWithdrawlofMoneyfromDesginated Account) Date'.26lt7l2ol7 To The ll/S SHREE SAI SAKAR BUILDERS AND DEVELOPERS 4/7f /4T opp. Z.P. Affice Aurangpura, Aurangabad Maha ra shtra Subject:certificateofPercentageofcompletion-ofconstructionworkof0lNoofBuildingoftheProiect P demarcated bY its boundaries Registration uurnu"ri- sitrut"d on the plot bearing No 17/ Gut No-47 tMahaRERA noaa to tr'e North plot No15A And 168 in south Plot No-19 to the East (latitude and longitude of the en;'poi;;; . Admeasuring 422'97 sq'mts' taluka Aurangabad District Aurangabad Road to the west at ttkheda or;r;;;; BUILDERS AND DEVELoPERS .r* u""g a1r"f"ped bv l a sHREi slt slx'm Sir, Surveyor of assignment as ArchitecvLlcensed l/We Sakar Associates have undertaken situated on the of Construtt'?"' *"1-:-f- 01 No of Building of the Project Certificate of Percentage of Completion taluka Aurangabad District Aurangabad ' Admeasuring 42297 plot bearing No 17/ Gut r.ro at nktela Aurangabad bv tiilix*iill tottm BuILDERS AND DEvELoPERS sq.mts. area beins developed by owner/Promoter:. 1. Following technical Professionals are appointed l' Shri' Kedar Pande L'S' /Archltect' consultant ff iiti' pi'*a Aphale as structural MEP Consultant lll' Shri' Kedar Pande as Site lv' Shri' Sanjay Santre as Supervisor aforesaid respect to the Building of the Based on site lnspection with the percentage of that as on the date of this Cerificate ' Rea[ Estate Proiect, t Certw as registered vide of the Real Estarc Project Work Done for each of Building^Ving A herein below' The Percentage under MahaRERA is as per table number details in Table B' of the work executed with respect to each of the activity of the entire Phase is Percentage of Work done Sr.No- Tasks /Activity Excavation 100% 7 2 number of basements and Plinth 1 I00% N.A 3 number of Podiums Stilt Floor 0 4 6 5 number of Slabs of SuPer Structure 7Oo/" 6 Internal Walls, lnternal Plaster, F loorings Within Flats/Premises, Doors and windows To each of the Flat/Premises m% 7 Sanitary Ftttings Wathin the FIat/Premises Etectrical Fittings within the Flat/Premises 100% 8 Staircases, Lift wells and Lobbies at each Floor level Connecting Staircases and Lifts, Overhead and Underground Water Tanks The extemal Plumbing and external Plaster too% 9 Elevation, completion of terraces with water Proofing of the Building/Wing lnstallation of lifts, water pumps, Fire Fig hting 80% 10 Fittings and Equipment as per CFO NOC, Efectrical Fiftings to Common Areas, eaectro Mechanical equipment Compliance to I conditions of environment /cRz NOc, Finishing to entrance Lobby/s, Plinth Protection, paving of areas appurtenant to BuildingAVing, Compound Wall and all other Requirements as may be required to obtain Occupation/Completion Certificate. TABLE-B lnternal &extemal Development Works in Respect ofthe entire Registered phase S.No Common areas and Facilities, Proposed Percentage of Deta ils Amenities (Yes/No) Work done 1, lnternal Roads & N.A N.A N.A Foothpaths 2 Water Supply YES LOg% 3 Sewarage(Chamber, lines, YES 100% Septic tenk sIP) 4 Storm Water Dra ins N.A N.A N.A 5 Landscaping & Tree Planting 6 Street Lighting N.A N.A N.A 7 Community Bu ildings N.A N.A N.A 8 Treatment and disposal of YES 100y" sewage and sullage water 9 Solid Waste management & YES t00% Disposal 10 Water Conservation, Rain water YES 100% harvestlng 11 Energy Management N.A N.A N.A 12 Fire protection and fire safety N.A N.A N.A requirements 13 Electrical mete room, Sub- YE5 LOO% station, Receiving station !4 Others (Option to Add more) N.A N.A N.A Youres Faithfully FOR SAKAR ASSOCIATES AR. KEDAR PANDE Signature & Name (lN BLOCK LETTERS)of L.s./Architect License No. 22917