PORM-2A (Sce MahaRERA order No. Of 2018) ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE To BUILDING, TheSARA INFRASTRUCTURES, SARA SWAPNANGAN, A4,A5,A6 TALUKA & DISTRICT GUT NO.93 P AND 95 P, GANGAPUR JAHANGIR, AURANGABAD Quality Assurance Certificate July-2021) (Certificate No. FORM -2A for the quarter of materials uscd and quality of Construction Subject:- Certificate lor quality Wings(s) of the the Work of 3 No. off buildings(s)/ 3 n d workmanship for AND 95 P, NO.93 P SARA INFRASTRUCTURES of the project situated GUT demarcated its by TALUKA && DISTRICT AURANGABAD, GANGAPUR JAHANGIR, INTERNAL PATHWAY to of the end points) boundaries (latitude and longitude South, 12 MTR WIDE ROAD to the East, ROAD to the the North, INTRENAL PROJECT to the West, of Division GROUP HOUSING OPEN SPACE OF SAME JAHANGIR, Taluka Aurangabad, GANGAPUR JAHANGIR, village GANGAPUR Pin-431007, admeasuring 2552.10 Sq. Mtrs. area being District Aurangabad, INFRASTRUCTURES. developcd by SARA P51500001363. Relerence: MahaRERA Registration Number Sir of this I MR. KISHOR DANDGE have undertaken an assignment of supervision real estate project. 1. Our Responsibility: To Carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed code of practice. specification, and as per NBC and or other relevant 1. Material Testing: checks on the basic 1/We have applied following mandatory constructions. materials, used in the i. Cement: been tested for its fineness, soundness, setting time, it has relevant IS code 3535:1986 or a s per other compressive strength etc. a s per standards and its results are within the IS/BS/NBC code or a s per industry permissible limits. ii. Coarse aggregate: deleterious materials, clay lumps, crushing it has been tested, for relevant 1S/BSNBC IS 2430:1986 or a s per other value, impact value a s per within the permissible standards and its results are code or a s per industry limits. ii. Bricks/blocks: - crushing strengths etc. as They have been tested for water absorption, code or a s pr industry a s per other relevant IS/BS/NBC per IS 5454:1978 or limits. standards and its results are within permissible iv. Concrete/Ready-mix Concrete for various periods as per It has been tested for compressive strength relevant IS/BS/NBC codes, a s per IS 456:2000 and 1S 1199 or as per other within permissible limits. industry standards and its results are v. Steel for concrete: It has been tested as per 1S 2062:2011 or as per other relevant Is/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials: Other materials like sand, crushed sand, floor tiles, fixtures, and fittings, pipes and sanitary fittings etc. (List out all items ) used in this project conlorm to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship: under our 1/we hereby certify that work has been carried out and quality is satisfactory supervision. We further certify that workmanship and up to the mark and the work has been acceptable within the permissible limits off deviations as per relevant code of practice. 3. Electrical Materials and workmanship: works of all the electrical wiring / connections /lit installations have been carried out under installation/ other electrical records has been maintained. authorized /registered electrical engineer and its relevant I.S/B.S/ National Building codes or The materials used conform to the as per industry standards. 4. Structural engineer: structural engineer Mr. N G Promoters has engaged office No.-0240-2452305 KARKHANE having Licenses No.-AMC-59/89 having cell No. 9823028081 The structural design of project has been buildings in this checked the soil report before laying PCC done under his supervision. He has with soil consultant. The formwork and concrete for foundation in consolation mix design has been done a s per IS 10262:2009 or a s per other relevant codes checks and certificates for STABILITY and SAFETY as His applicable. periodic have been kept on record. s. Preservetioa of records have been properly kept Recorda all test results of this project the defect liability formats and will be presened at least up to in thie prescnibed br anv other provision off law period o r for the perd a s required were not other item off works which Please speczh matenals or an not rejected. seicatons and which were conformang to the siard. 1 Colorng 2-Alumunum. 3 Doors < s Fitung Tiles 5-CP & sanitar Yours Failtihfally. sigaatyieofSuperviso Name: MR. KISHOR DANDGE Phone No: - 8007786314 Flace:-Aurasgabad.