S.r-&-Jfr-&ilil (D C.E ) GIVIL ENGIN EERING CONSULTANT i Planning a Estimates l Supervision & Turn Key Works Ref.No. Date : FORM-2A [See Regulation 3A.l ENGINEERS'S CERTIFICATE FOR QUALITY ASSURANCE (Site Supervisor's Certificate) (To be submitted at the end of Financial year) oate: Lo/t7/to2f To, The SHIKHAR INFRA Nanded Waghala (M Corp.), Nanded, Nanded,431601 Quality Assurance Certificate . ......................for the year Ending ..... .2025....... ..) (Certificate No. 066/CR/297040 Subject : Certificate for quality of materials used and quality of Construction and workmanship of the work of SANMAN SHIKHAR having MahaRERA Registration Number P5l100O79711being devetoped by SHTKHAR TNFRA Sir, l/vve A.M.Adil .....,................ have undertaken an assignment of supervision of this real estate project Our Responsibility To carry out the work in accordance with the development permission and as per the approved plan, to submit certificate of supervision of work, to carry out material testing in-situ or in an authorized laboratory as per prevailing and applicable standards, to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and / or other relevant code of practice. The details of the quality are as follows : 1. Structural Design, Stability and Testing Sr. No. Yes/No Remarks 1 Whetl.er soil investigations of the site has been Yes GOVY.POLYTECNIC conducted before the structural design and soil parameters have been accounted for in the q[qqlural desi gn/d rawinos? 2 Whether Skuctural Engineer has been appointed for Yes Name: RAJENDRA BIRLA the project? Lrcense No: DDMCWR/2021lAP100262 Mobile: 9423080479 \ E-mail:e-raiendrabirla@omail.com $ 3 Whether the inspection registers, site order book Yes ArsrrE and quality control test registers are maintained at the site propedy and endorsed by the Engtneer-tn- .n, %.. fl@u ) Charge? D.C.E. .rtimiit0ll4[slclE$/u 4 Whether testino facilities to check oualitV of material Yes nvntLnBLE srsye{abte'at dtsE:l;;:;=^, ^- - cell:9766412844 Emait :musayyabadit@gmait.com BTE ceftficate No.066/cRi2970a0 Sr. No. Parameters Yes/No Remarks . 5 Whether the statuary provisions for disaster Yes YES AS PER NBC resrstance/earthquake resistant deslgn have been rncorporated, specially in case of multi-storeyed construction? 6 Has suitable coonizance been taken on demarcated Yes YES PROTECED flood lines and Sppropriate precautions taken for protecting the site from flooding considering local floodino issues? 2. lnput Materials Sr. No. Parameters Yes/No Remarks 1 Whether the following building materials confirm to Yes YES relevant IS/BS/NBC Code, or as per lndustry Standards? lf yes, provide detailsl {a) Cement, concrete and coarse agg!999!q Yes s 456 (b) Steel and its alloys Yes FE415 (c) Electrical wire, fittinqs and accessqlieq Yes tst (d) Plumbino and sanitarv fittinqs Yes rst 2 Whether reoular tests of materials and construction Yes MARATHWADA TESTING LAB products arE being done from accredited labs also? lf ves. details of such labs 3 Whether manufacturer test certificate for cement, Yes YES steel, pipes etc. have been obtained and whether sunolv records are beino maintained? 4 Whether suitable water is being used for Yes S 456 PH VALUE 6 TO 8,5 construction? (i) What is the source of water? Yes BOREWELL (ii) Has water been tested and approved by Yes YES Fnoineer-in-Charoe before construction? (iii) Has water been tested subsequently as per Yes AT GOVT.LAB TESTED reouirement? 3. Quatity of Workmanship Sr. No. Parameters Yes/No Remarks 1 Whether works of all the eleckical Yes ELECT,CONSULTANT RAGHUNATH wirino/connections/lift installationiother electrical GROUP OF COMPANIES rnstaiiations have been carried out under authonzed/registered electncal engineer and whether records of the same has been maintained? 2 Whether all related works of plumbing & sanitary Yes MEP. CONSULTANT RAGHUNATH includinq installation of water supply systems, GROUP OF COMPANIES drainag6 systems, sewage systems, sinks, toilets etc. have been carried out under authorized/registered plumbers/sanitary contractors and whether records of the same has been 3 Whether all the work is being carried out under Yes YES supervision of experienced and skilled professional? Fu'rther, whether ihe workmanship and quality is satisfactory and up to the mark and the work is within the icceptable and permissible limits of dcviAiions as oer relevant Code of Practrce? A, fiil, D,C.E. OIt Caificar [all6Slctrn0rUd Page 2 of3 Sr. No. Parameters Yes/No R6marks 4 Whether remedial measures are undertaken to Yes ULTRATECH WEATHER PRO prevent dampness and leakages? lf yes, provide details 5 Whether safety precautions are undertaken during Yes HELMENTS, HARNESS AND SAFETY construction aativities for all tvpe of workers? 4. Miscellaneous Sr. No. Parameters Yes/No No 1 Whether third party quality inspection is being Yes MARATHWADA MATERIAL TESTING carried out on site during/after completion of the LAB works? lf ves, provide details. 2 Whether anti-termite treatment has been undertaken Yes CHLORPRIFOS IS USED for the soil? 3 Whether fire-fighting arrangements has been Yes DHANSHREE FIRE SERVICES undertaken under supervision of fire consultant? 4 Whether orooer sionaoes have been installed on Yes YES site/comdletdd bui-ldin6 as Der requirement? 5 Whether Drecautions are undertaken to avoid air Yes Readv Mix Concrete is Used And Water Dollution aurino construction? Please specify. Soriniler ls Used Before Movinq Dust 6 Whether records of all test reports/results have been Yes YES properly kept in the prescribed formats and whether ihe same are available at site for viewing by allottees and to be handed over to the association of allottees? 7 Whether all relevant records including sanctioned Yes YES At Site building plans, utility drawings, various test reportsJrasults have been properly kept in the prbscribed formats to be handed over to the association of allottees? 8 Anv innovative/cost effective/green technology has Ready Mix Concrete ls Used be6n used for improving qualityienergy efficiency? \ Please soecifv. \ Yours Faithfully .n, w. D.c.E. trrtcrrft.uxo.qtrifrzomr \ Signature of Engineer (Site Supervisor) Name: A l,/ ADIL Qualification (Not less than graduate) License No. (if any): 066/CR/297040 Phone No: q7/6.t | 2^844 Place: NCntLy' Agreed and accepted by SIDDHANT Digitally signed by SIDDHANT SATISH SATISH MAHESHWARI Date: 2025.08.06 MAHESHWARI 16:24:36 +05'30' Signature of Promoter Name: SHIKHAR INFRA Dare: lo/s7/2s2g' Page 3 of3