Consulting Engineers . R.C.C. Consultant . Steel Design Consultant . Er. Rajendra g. Birla Registered Valuers . M. Tech- Slructures (l.l.T. Bombay) B.E. Civil (Hons.) Chartered Engineers . F.l. EiM.l.C.l.(U.S.A. ) F.l.V; Stability of Structures . L.M.S.T-E:L.M. 21648 R G B StructuralAudit . Gold Medalist of l.l.T- Bombay FORM 1 (See Regulation 3) ARCHITECT'S CERTIFICATE for (To be submitted at the time oinegistration of Ongoing.Project and ' withdrawal of Money from Designated Accounr) Dalei 2Ol04/2024 To, M/s M B Builders & DeveloPers, Nanded Work of A R Subject: Certif ica te of Percentage of Completion of Construction P511oOO55O45 be in9 Khiyani City having MahaRERA Registration Number devetoped by M/s M B Builders & Developers Sir, as Architect/ Licensed I/+fe, M r. Raiendra Birla have undertaken assignment of Construction Work A R Khiyani Surveyor of certifying Perceniage of Completion beinq developed by City having MahaRERA Registration Number P511ooo55o45 M/s M B Builders & DeveloPers' Layout / each of the Building/Wing of Based on Site Inspection' with respect to on the date of this certificate' the aforesaid Real Estate p'o:"tt' it"ttifV that as of the Real Estate the Percentage of Work Oonliio' each of the building/Wing Project under MahaRERA p-"t-iJf u A herein below The percentage of the work executed with respect 't'u'' to J*n activity of the entire phase is detailed "itr',r" in Table B. Page l1 2O'l,2nd floor, AmarArcade, Kulkarni Colony, Sadhu Waswani Road, Nashik - 5 03, W1O, Amara, Kolshet Road, Thane. (W) 400 60l , Cell }423OAO47 9, 982297 5229, e-rajendragbirla@gmail com Table A Lavout/Building/wing Number A R Khiyani City (to be preoared separatelv for each Lavout /Buildino /Wing of the Project) Percentage of Actual work Sr, Tasks /Activity done (as on the No (2) date of (1) certificate) (3) 1 Excavation 100 2 Basements (if any) 100 3 Podiums (if any) 0 4 Plinth 100 Stilt Floor 20 6 Slabs of Su r Structu re 70 7 Internal walls, Internal Plaster, Floorings, Doors and 20 Windows within Flats/Prem ises B Sanitary Fittings within the Flat/Premises 20 9 Staircases, Lifts wells and Lobbies at each Floor level 20 Overhead and Underground Water Tanks 10 The external plumbing and external plaster, elevation, 20 completion of terraces with waterproofinq of the Building/Wing, 11 Installation of Iifts, water pumps, Fire Fighting Fittings 20 and Equipment as per CFO NoC, Electrical fittings, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Win9, Compound Wall and all other requirements as may be requrred to complete project as per specifications in agreement of sale. Any other activities Page l2 TABLE- B Common Areas (Internal & External DeveloDment Works l in ResDect of the Reoistered Phase/proiect number Percentage of Actual Sr, Proposed Work done Details Common areas and (Yes/No) (as on the No. (s) (1) Facilities (2) (3) date of certificate) (4) 1 I nterna I Roads & No NA Footpaths 2 Water Su pply Yes NA 3 Sewerage (chamber, Yes NA lines, Septic Tank, STP) 4 Storm Water Dra ins No NA 5 Landscaping & Tree No NA Pla nting 6 Street Lighting No NA 7 Community Buildings No NA 8 Treatment and d isposa I No NA of sewage and sullage water 9 Solid Waste No NA management & Disposal 10. Water conservation/ No NA Rain water ha rvesting 11. Energy management Yes NA 72. Fire protection and fire Yes NA safety requirements 13 Electrical meter room, Yes NA sub-station receiving station 14. Others (option to add more) Page l3 ---I Yours faithfully, For, Rajendra Birla & Associates Mr.Rajendra Birla (Proprietor) Local Authority License No.: SI ATE/R12022/ APV03976 W'ryg.b Agreed andlffited by: M/s M B Builders & Developers ilBBdm &0flelopers signature "ffi, Name: Mr. Jugalkishore Khiyani Dare'.20/04/2024 Page l4