SHIRISH GOVIND PUROHIT Architect 18, Z.P. COMPLEX, STATION ROAD, NANDED. ph. No. 98230100Sd FORM 1 [see Regulation 3] ARCHITECT'S CERTIFICATE (To be submitted at the time of Registration of Ongoing project and for withdrawal of Money from Designated Account) Dale:2710712017 To, M/s Jinen Developers, Sai Heights, Old B K Hall, Shrinagar, Nanded. subject : certificate of Percentage of completion of construction work of Sai Heights of the Project [MahaREM Registration Number] situated on the plot crS No..18633 demarcated by its boundaries (latitude and longitude of the end points) D p ROAD to the North POLICE COLONY to the South PLoT oF NILEKAR to the East iNTERNAL RoAD to . the West of Division village NANDED taluka NANDED District plN 43i602 admeasuring 3494 sq.mts. area being developed by M/s Jinen Developers Sir, - l/ We Shirirsh Purohit have undertaken assignment as Architect /Licensed Surveyor of certifying Percentage of Completion of Construction Work of the Sai Heights Building of the project, situated on the plot CTS No.18633 of Division - village Nanded tatuka Nanded District N jnded ptN 431602 admeasuring 3464 sq.mts. area bEii-g developed by M/s Jinen Developers 1. Following technical professionals are appointed by Owner / promoter :_ (l) Shri Shirish Purohit as L.S. / Architect ; - (l/) Shri Rajendra G Birla as Structural Consultanl (,r) Shri Rajendra G Birla as MEp Consultant (lrz) Shri Lalit M Chavan as Site Supervisor Based on Site lnspection, with respect to each of the Buildingl/Ving of the aforesaid Real Estate Project , I certify that as on the date of this certificate, the Percentage of Work done is 88.41% for Sai Heights building of the Real Estate Project as registered vrde number under MahaREM is as per table A herein below. The percentage of the work executed with respect to each of the activity of the entire phase and overall percentage of.&ork done . .. is detailed in Table B. .. ' :,) ., , li. -- SHIRISH GOVIND PUROHIT Architect 18, Z.P. COMPLEX, STATION ROAD, NANDED. ph. No. 98230100S6 TABLE-A Building n/ving Number-(to be prepared separatery for each Buirding A/ving of the project) Sr. No. Tasks /Activity Percentage of work done (1) (2) (J,l 1. Excavation 100o/o 2. I number of Basement(s) and plinth 1O0o/o 0 number of Podiums 100% 4. Stilt Floor 100% 5. 7 number of Slabs of Super Structure 100o/o o lnternal Walls, lnternal Plaster, Floorings within Flats/Premises, Doors and Windows to each of 100o/o the FlaUPremises. 7. Sanitary Fittings within the FlaVpremises, 1000h Electrical Fittings within the FlaUpremises. 8. Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts,Overhead 100yo and Underground Water Tanks. o The external plumbing and external plaster, elevation, completion of terraces with 600/o waterproofi ng of the BuildingArVing. 10. lnstallation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to condi- tions of environment /CRZ NOC, Finishing to 30o/o entrance lobby/s, plinth protection, paving of areas appurtenant to BuildingAlVing, Compound Wall and all other requirements as may be required to obtain Occupation / Completion Certificate. SHIRISH GOVIND PUROHIT Architect 18, Z.P. COMPLEX, STATION ROAD, NANDED. ph. No.9823010056 TABLE-B lnternal and External Development works in respect of the entire Registered phase. S. No. Common areas Proposed Percentage of and Facilities, (Yes/No) Work done Amenities (1) (2) (3) (4) (5) 1. lnternal Roads & Footh-paths. Yes 100% Water Supply Yes 100% J. Sewarage (chamber, lines, Yes 't00yo Septic Tank ,STP) 4. Storm Water Drains Yes 1000/o ( Landscaping& Tree Planting. Yes 100o/o b. Street Lighting Yes 1O0o/o 7. Community Buildings Yes 80% 8. Treatment and disposal of sewage and sullage water. Yes 100Y0 9. Solid Waste management & Yes 100o/o Disposal. 10. Waterconservation, Rain water harvesting. Yes 1O0o/o 1 1. Energy management Yes 1lYo 12. Fire protection and fi re safety requirements Yes 300/0 13. Electrical meter room, sub-station, receiving Yes 10oo/o station. 14- Others ( Option to Add more). -: v-: Yours Faithfully, I I Ar. Shtuhh.rtit (C.Arch. A.t.t.L) c.n0722177 tr, ZP Shgp|frg Corfphr, rrmfi