I. The Maharashtra Real Estate Regulatory Authority (General) Regulations 2017 Form-2A ENGINEER,S CERTIFICATE FOR QUALITY ASSURANCE ( site supervisor's certificate) (to be uPloaded quarterlY) To, TheShri. Mahendra Shravan Bokade & 7 Other. Gujari Ward, Bramhapuri-44t205 Qualitv Assurance Certificate (Certificate no. P5090002357t for the quarter ending t0lOSl2O2Ol Subject: Certificate for quality of materials used and quality of construction and workmanship for the workof SinglePhase of the project"Bokade Layout" [P50900023571]situated on the Plot bearing csrrsl€14+S-$le./ Survey No. 1447 demarcated by its boundaries layout of Naidu pise totheNorth, Boundaries of Delanwadi - BramhapuritotheSouth, layout of Naidu pise and Wairkarto theEast, layout of Tushar Raut to the West, Division- Nagpur, Village- Bramhapuri, Taluka- Bramhapuri District-Chandrapur,PlN: 441205 admeasuring 12100.00 Sq.m. area being jointly developed by Shri. Mahendra Shravan Bokade & 7 Other' Ref: MahaRERA Registration NumberP50900023571 Sir, l/We SachinKadhikhaye have undertaken anassignment of Supervision of this Real Estate Project, 1. OurResponsibilitY:- To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. L. MaterialTesting :- in the t/we have applied following mandatory checks on the basic materials used construction. t. Cement - It has been tested for its fineness, soundness, setting time, compressive code, strength etc. as per ls code 3535:1986 or as per other relevant ls/BS/NBC the permissible limits' or as per industry standards and its results are within ll. Coarse aggregate - impact It has been tested, for deleterious materials, clay lumps, crushing value, value as per ls 2430:7986 or as per other relevant ls/BS/NBC code or as per industry standards and its results are within the permissible limits' llt. Bricks/ Blocks - as per ls They have been tested for water absorption, crushing strength etc' 5454:!9780r as per other relevant IS/BS/NBC code or as per industry standards and its results are within permissible limits' !v. Concrete/ ReadY-mix Concrete - It has been tested for compressive strength for various periods as per ls per industry 456:2000 and lS 1199 or as per other relevant IS/BS/NBC code or as standards and its results within permissible limits' V. Steels for concrete - code It has been tested as per lS2062:2011 or as per other relevant IS/BS/NBC gauge length or as per industry standards for tensile strength, elongation and etc. and its results are within permissible limits' vl. Testing of other materials - Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes project conform to and sanitary fittings etc' (List out all items) used in this relevant IS/BS/NBC code or as Per standards laid down by the industry for a particular material. 2. WorkmanshiP:- l/We hereby certifY that work has been carried out under our supervision. we further mark and the work has certify that workmanshiP and quality is satisfactory and up to the been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship :- Work of all the electrical wiring/ connections/ lift installation / other electrical installations have been carried out under authorized / registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structura! engineer :- Promoters has engaged structural engineer Mr.SachinKadhikhave having Licenses no.------ ------ having office no. ---------------- cell no. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per lS tO262:2O09 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY has been kept on record. 5. Preservation of records :- Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 5. Please specify materials or any other item of work which were not conforming to the :",. T.:: ::::t::T: :yTl.::: ::l rejec'[ed Signature of Engineer (site supervisor) Name: SachinKadhikhave License no. (if any): t Phone no.: QUz36 \ C\2-2-lt I